BLD-Final | 12/5/2006 | 12/6/2006 | 12/6/2006 | A | PASS |
Mike Jordan
|
|
|
ben - call for access ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
|
DOC - Permit Finaled | 12/6/2006 | 12/6/2006 | 12/6/2006 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Energy code compliance | 10/3/2006 | 10/4/2006 | 10/4/2006 | P | PASS |
Mike Jordan
|
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. All framing issues have been resolved.
|
BLD-Framing/Rough-in | 10/2/2006 | 10/3/2006 | 10/3/2006 | A | FAIL |
Mike Jordan
|
|
|
###-####. Complete lateral bracing, A07T-A012T trusses. Min. 3 8d nails at truss connections needed. 2 ply girder trusses nailed insufficiently on bottom chords. Provide additional 2x on wall under 2ply 9.5 ML at furnace, east wall. Justify sub of 2 ply 9.5 ML for 4x8 header from garage to house. c/n posted. ok to insul.
|
BLD-Footing | 9/5/2006 | 9/5/2006 | 9/5/2006 | P | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 9/5/2006 at 7:18:18 AM. Contact: ###-####.
|
BLD-Footing | 8/25/2006 | 8/28/2006 | 8/28/2006 | P | CANC |
Mike Jordan
|
|
|
matt; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Canc by contractor.
|
Issue PAID IN FULL permit | | | 8/23/2006 | | DONE |
|
|
|
|
Plan assigned to (SRZ) | 8/10/2006 | 8/10/2006 | 8/14/2006 | | PASS |
|
|
|
8/14/2006 08:58:05 SRZ - activity updated through activity BLDA022 from case BLD06-02241.
|
Routing - PLAN CHECK | 8/3/2006 | | 8/14/2006 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/14/2006 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/14/2006 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 8/14/2006 | | DONE |
|
|
|
|
Telephone call | | | 8/14/2006 | | DONE |
|
|
|
Spoke with Rebecca and told her that permit is ready & fees///8/14/06 @ 10:00am BAS
|
Plan assigned to (SAM) | 8/2/2006 | 8/2/2006 | 8/10/2006 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 8/10/2006 | | |
|
|
|
|
Routing - PUBLIC WORKS | 8/3/2006 | | 8/3/2006 | | PASS |
|
|
|
|
Routing - PLANNING | 8/3/2006 | | 8/3/2006 | | PASS |
|
|
|
|
Routing - Addressing | 8/2/2006 | | 8/3/2006 | | PASS |
|
|
|
|
Application received | | | 8/2/2006 | | |
|
|
|
|