(F) Reprint permit | | | 1/2/1998 | | |
|
|
|
|
INSP - Letter of compliance | 12/19/1997 | 12/19/1997 | 12/19/1997 | | PASS |
Jim Storey
|
|
|
/ / 301 - LCI-LETTER OF COMPLIANCE ISSUED 14208
|
INSP - Letter of compliance | 12/19/1997 | 12/19/1997 | 12/19/1997 | | PASS |
Jim Storey
|
|
|
/ / 301 - LCI-LETTER OF COMPLIANCE ISSUED 14208
|
INSP - Final | 12/19/1997 | 12/19/1997 | 12/19/1997 | | PASS |
Jim Storey
|
|
|
12/19/97 301 - Final FNL -OK FINAL
|
INSP - Final | 12/19/1997 | 12/19/1997 | 12/19/1997 | | PASS |
Jim Storey
|
|
|
12/19/97 301 - Final FNL -OK FINAL
|
INSP - Letter of compliance | 12/19/1997 | 12/19/1997 | 12/19/1997 | | PASS |
Jim Storey
|
|
|
/ / 301 - LCI-LETTER OF COMPLIANCE ISSUED 14208
|
INSP - Letter of compliance | 12/19/1997 | 12/19/1997 | 12/19/1997 | | PASS |
Jim Storey
|
|
|
/ / 301 - LCI-LETTER OF COMPLIANCE ISSUED 14208
|
INSP - Energy code compliance | 11/28/1997 | 11/28/1997 | 11/28/1997 | | PASS |
Jim Storey
|
|
|
/ / 301 - INSL-OK INSULATION-ENERGY CODE
|
INSP - Framing/Rough-in | 11/26/1997 | 11/26/1997 | 11/28/1997 | P | PASS |
Jim Storey
|
|
|
11/26/97 301 - Wanted an additional inspection if you don't pass him at FRAM-OK FRAMING
|
INSP - Framing/Rough-in | 11/25/1997 | 11/26/1997 | 11/26/1997 | P | PART |
Jim Storey
|
|
|
11/26/97 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED ok to insulate
|
Telephone call | | | 11/24/1997 | | |
|
|
|
called acs - permit ready
|
Inspection Record Card- Bld | | | 11/24/1997 | | |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 11/24/1997 | | PASS |
|
|
|
|
Issue PAID IN FULL permit | | | 11/24/1997 | | |
|
|
|
|
Plan Reviewer's activity | | | 11/24/1997 | | PASS |
|
|
|
revised engineering recieved for structural analysis of reward basement foundation system.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/24/1997 | | DJO |
|
|
|
|
Plan assigned to (DJO) | 10/3/1997 | | 11/24/1997 | | PASS |
Dan Overy
|
|
|
11/24/97 14:52:01 DJO - this action updated by action script from <<>> in Case No. BLD97-2956
|
INSP - Conference | 11/18/1997 | 11/18/1997 | 11/18/1997 | | FAIL |
|
|
|
Conference w/Foundation supplier.#1. Product is not approved by this jurisdiction,no ICBO or supporting analysis (info from Bob G.). #2. Contractor proceeded beyond early start permit(framing stage).#3 Product not installed per manufactures requirements. #4 Foundation is to be removed and replaced w/conventional wall.
|
Meeting | | | 11/18/1997 | | FAIL |
|
|
|
On 11/17/97 reviewed the submittle information on REWARD WALL SYSTEM. this product has not been approved by ICBO, nor is it related to Polysteel Systems as indicated by Mr. Stout (product rep.). This information has been relayed to Mr. Stout, and the decision on the acceptance of the installed (early-foundation-start) product turned over to the inspection division for acceptance or removal .
|
INSP - Miscellaneous | 11/17/1997 | 11/17/1997 | 11/17/1997 | A | FAIL |
Jim Storey
|
|
|
11/17/97 301 - Place a swo on this project for unapproved material and i manufactures recomendations, #325. stop work posted...
|
INSP - Footings | 10/29/1997 | 10/29/1997 | 10/30/1997 | P | FAIL |
Jim Storey
|
|
|
10/29/97 301 - will you please check on the foundation between 2401 and that was poured w/o an inspection to see if the space between them are correct. no plan on site, p/l not able to find pins, fence is 5' from footing on side, early sta
|
INSP - Footings | 10/22/1997 | 10/22/1997 | 10/23/1997 | P | PART |
Jim Storey
|
|
|
10/22/97 301 - Early start - Hi rickshaw rider!! EAR-EARLY START POURED WITHOUT INSPECTION
|
Plan Reviewer's activity | | | 10/20/1997 | | PEND |
|
|
|
early start. basement wall constructed using reward foam block system. special inspection req. this product does not have a icbo report and is not approved. eng will be required.
|
Plans ACCEPTED BY PLAN CHECK | | | 10/17/1997 | | PEND |
|
|
|
|
Routing - PUBLIC WORKS | 10/6/1997 | | 10/7/1997 | | PASS |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 10/6/1997 | | |
|
|
|
|
Routing - PLANNING | 10/3/1997 | | 10/6/1997 | | PASS |
|
|
|
APPROVED BY RW.
|
Application received | | | 10/3/1997 | | |
|
|
|
|
Routing - PLAN CHECK | 10/8/1997 | | | | PEND |
|
|
|
|