INSP - Letter of compliance | 3/25/1998 | 3/25/1998 | 3/25/1998 | | PASS |
Russ Owen
|
|
|
/ / 407 - LC#15529. Inspection done 3/24/98 added in on the 25th.
|
INSP - Letter of compliance | 3/25/1998 | 3/25/1998 | 3/25/1998 | | PASS |
Russ Owen
|
|
|
/ / 407 - LC#15529. Inspection done 3/24/98 added in on the 25th.
|
INSP - Final | 3/23/1998 | 3/23/1998 | 3/23/1998 | P | FAIL |
Russ Owen
|
|
|
03/23/98 407 - left correction on the unit.
|
INSP - Final | 3/19/1998 | 3/20/1998 | 3/20/1998 | P | FAIL |
|
|
|
03/20/98 333 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
|
INSP - Wall cover | 2/25/1998 | 2/25/1998 | 2/26/1998 | P | PASS |
Russ Owen
|
|
|
02/25/98 407 - SHEER NAILING per john engineer ok 1/2"house side 5/8"gar
|
INSP - Framing/Rough-in | 2/23/1998 | 2/23/1998 | 2/23/1998 | | PASS |
Russ Owen
|
|
|
/ / 407 - re-insp. truss company has approved the girder at the front
|
INSP - Framing/Rough-in | 2/19/1998 | 2/19/1998 | 2/20/1998 | P | PART |
Russ Owen
|
|
|
02/19/98 407 - still have a truss correction,ok to rock except for the l called john and made him aware of the situation.
|
INSP - Energy code compliance | 2/19/1998 | 2/19/1998 | 2/20/1998 | P | PASS |
Russ Owen
|
|
|
02/19/98 407 - ###-####
|
INSP - Framing/Rough-in | 2/17/1998 | 2/18/1998 | 2/18/1998 | A | FAIL |
Russ Owen
|
|
|
02/18/98 407 - ###-#### JOHN
|
INSP - Framing/Rough-in | 2/3/1998 | 2/3/1998 | 2/3/1998 | P | PASS |
Russ Owen
|
|
|
framing/engineering talk to framer john ###-#### ###-####
|
INSP - Footings | 1/8/1998 | 1/9/1998 | 1/12/1998 | A | PART |
Russ Owen
|
|
|
01/09/98 407 - set backs ok,footings & walls poured before inspection.no
|
Issue PAID IN FULL permit | | | 1/8/1998 | | |
|
|
|
|
Inspection Record Card- Bld | | | 1/6/1998 | | |
|
|
|
|
Routing - PLAN CHECK | 1/6/1998 | | 1/6/1998 | | PASS |
|
|
|
|
Telephone call | | | 1/6/1998 | | |
|
|
|
GAVE DOLLAR AMOUNT TO SCOTTY
|
Plan assigned to (DJO) | 12/22/1997 | | 1/5/1998 | | PASS |
Dan Overy
|
|
|
01/05/98 11:50:04 DJO - this action updated by action script from <<>> in Case No. BLD97-3735
|
Plan Reviewer's activity | | | 1/5/1998 | | PASS |
|
|
|
HAVE ISSUED ALLOWING ENG. TO BE SUBMITTED AT FRAME. PLANS ARE RED-LINED INDICATING SUCH. OTHER INFORMATION NEEDED HAS BE SATISFIED.
|
Print Pending Permit.LaserJet4 | | | 1/5/1998 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 1/5/1998 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 1/2/1998 | | PEND |
|
|
|
ENG. REQ. FOR WALL BRACING. NO LIFE/SAFETY NOTES. NEED ROOF FRAMING.
|
Plans ACCEPTED BY PLAN CHECK | | | 1/2/1998 | | PEND |
|
|
|
|
Office Staff conference/action | | | 12/24/1997 | | |
|
|
|
TOOK TO PLAN CHECK DAN O/12/24/97/PE
|
Routing - PUBLIC WORKS | 12/22/1997 | | 12/23/1997 | | PASS |
|
|
|
|
Application received | | | 12/22/1997 | | |
|
|
|
|
Routing - PLANNING | 12/23/1997 | | | | PEND |
|
|
|
|