Permit Information
Permit NumberBLD98-01723
StatusFinaled
Name SARMC MEDICAL BUILDING FIVE
Site Address 900 N LIBERTY ST
Project NameST ALS OFFICE #5
Customer Number 
ePlanReviewNo
Description
To install listed smoke stop assemblies on the three elevators opening into the first floor lobby's. One on the North end elevator (smoke door) by the exterior stair enclosure entry and two (Smoke Guard Systems) on the elevators located within the West side main entrance lobby, required because of the I1.1 Occupancy located on the fourth floor which negates the "B" office occupancy exception allowing main floor doors opening into a one-hour rated, fully sprinkled lobby, to not have smoke protection. Units to be installed per manufactured approved listed instructions and Structural and Fire Departments field inspectors review and approval. Maintain fire-resistive rating of shafts and corridor areas with approved fire stop systems. All per approved plans. Separate electrical permit & approval required. NOTE: Building is fully fire sprinkled.Have manufacture's approved listing and installation specifications on site for review and use by electrical, structural & fire inspectors for final approval. A letter of completion is required as evidence of inspections, finals and conformance with approved plans & attachments. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - L/C Approved  1/27/1999 PASS
made ok # 015892
INSP - Final11/16/199811/16/199811/16/1998 PASS
DetailsJoe Tawney
/ / 406 - FINAL OK FOR CERT OF COMPLETION ON INST OF SMOKE GUARDS & DO
INSP - Framing/Rough-in10/30/199810/30/199810/30/1998PPART
Details
11/02/98 338 - made ok to cover and complete all framing etc. ele signe
Issue PAID IN FULL permit  6/22/1998
PLANS/APPL TAKEN TO FRONT DESK  6/15/1998 PASS
Print Occupancy Form  6/15/1998
Inspection Record Card- Bld  6/15/1998
Telephone call  6/15/1998 PASS
LEFT MESSAGE WITH HEATHER JONES AT ###-#### FOR SCOTT WENDALL THAT PLANS ARE READY
Routing - PLAN CHECK6/12/1998 6/13/1998 PASS
Will issue as a desk permit with fire department inspection and approval in the field as a condition of final and issuance of completion letter.
Print Pending Permit.LaserJet4  6/13/1998 PASS
Plan assigned to (DRS)6/10/1998 6/13/1998
DetailsDan Stuart
Application received  6/10/1998
Meeting  4/22/1998
Met with Bob Ross of Kreizenbeck Constructors concerning question that had been raised concerning protection of elevators on the ground floor against smoke infiltration by construction of an elevator lobby or installation of additional doors at elevator openings. The building had originally been viewed as an office building, "B" occupancy which, under provisions of exception #1 to 1005.10, would not require the lobby or added doors when the lobby floor is fully sprinkled. The problem was the installation of an I1.1 occupancy on the fourth floor and another had been proposed for the third floor but the project evidently cancelled. Since the area of the "I" occupancy(s) would involve more than 10% (sec. 504.3)of the area of the floor on which it is located the facility could no longer be classified an a "B" occupancy allowing use of the exception previously noted. This had been the policy used at past mixed occupancy uses. I explained this to Bob Ross and told him I would verify this interpretation through Marlene Southard, Plan Check Manager, and provide a response to him in writing. This was done and a copy is in the builing file.