Final | 3/16/2010 | 3/17/2010 | 3/18/2010 | P | PASS |
Jack Frank
|
|
|
please call 30 min prior to meet//Morgan Phone #: ###-####
|
(F) Reprint permit | | | 2/26/2010 | | DONE |
|
|
|
|
Final | 2/10/2010 | 2/16/2010 | 2/16/2010 | A | FAIL |
Jack Frank
|
|
|
morgan - please call 1/2 hr prior Phone #: ###-#### needs to update permit for 1 hot tub and up too 20 KW of elect heat, needs inuse covers, gfci for ceiling haeter and garage door opener recepts, only bathrm fan,light, and recept shall be on bath rm 20 amp circuit
|
Change Status to I | | | 2/10/2010 | | DONE |
|
|
|
reopened per rita so that homeowner can get final inspection
|
ELE-Aging Inspection | 1/22/2010 | 1/22/2010 | 1/25/2010 | | CANC |
Jack Frank
|
|
|
|
DOC - Permit Expired | 1/25/2010 | 1/25/2010 | 1/25/2010 | P | PASS |
Jack Frank
|
|
|
|
Electrical Rough-In | 7/16/2008 | 7/16/2008 | 7/16/2008 | P | PASS |
Bob Reichert
|
|
|
Morgan- call 30 min prior to going Phone #: ###-#### corrections made, ric ok, can't add esc inspection
|
Electrical Rough-In | 7/15/2008 | 7/15/2008 | 7/15/2008 | P | FAIL |
Bob Reichert
|
|
|
Morgan Please call 30 min before going out Phone #: ###-#### met owner, gave corrections, NEC 300.14 at least 6" free length conductor shall be left at each box where it emerges to splice or terminate, 312.5 shall provide abrasion protection for all conductors entering box,250.80 metal enclosures shall be grounded
|
Electrical Rough-In | 6/10/2008 | 6/11/2008 | 6/11/2008 | A | PASS |
Mike Kinnear
|
|
|
Morgan Phone #: ###-#### ok cover under ground conduit off out building
|
Electrical Rough-In | 6/9/2008 | 6/10/2008 | 6/10/2008 | P | CANC |
Bob Reichert
|
|
|
Morgan Phone #: ###-####
|
Electrical Rough-In | 5/29/2008 | 5/29/2008 | 5/29/2008 | P | PASS |
Bob Reichert
|
|
|
morgan Phone #: ###-#### soffits only ok to cover
|
Electrical Rough-In | 5/12/2008 | 5/12/2008 | 5/12/2008 | P | PASS |
Bob Reichert
|
|
|
Morgan ###-#### ok to cover u/g house to shop only
|
Electrical Rough-In | 5/9/2008 | 5/12/2008 | 5/12/2008 | A | PART |
Jack Frank
|
|
|
Morgan; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok for cover except at house end u/g shall be 18"
|
Electrical Rough-In | 5/2/2008 | 5/5/2008 | 5/5/2008 | A | PASS |
Bob Reichert
|
|
|
morgan Note: unifer please call 1/2 hr prior to inspection Phone #: ###-#### ok to pour concrete encased electrode at shop only
|
Conference | 4/29/2008 | 4/30/2008 | 4/30/2008 | P | DONE |
Bob Reichert
|
|
|
morgan- call 1st 1/2 prior to insp Phone #: ###-#### talked about plan for new shop and when to call for inspection, grounding, and burial depth
|
Application received | | | 4/29/2008 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 4/29/2008 | | DONE |
|
|
|
|