Temporary Service | 11/12/2009 | 11/12/2009 | 11/12/2009 | P | PASS |
Jack Frank
|
|
|
Reinspection on Temp Poles after fail Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe t/s u/g new ok
|
Temporary Service | 11/11/2009 | 11/12/2009 | 11/12/2009 | A | FAIL |
Bob Reichert
|
|
|
Temp pole inspection Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe called, left correction notice, NEC 250.53(G) grounding electrode shall be driven to 8' depth except where rock encountered, shall be driven at angle not to exceed 45 degrees from vertical, BCC job id sticker shall be posted, fee due, no esc this project
|
Reinspection Fee (no hold) | 11/12/2009 | 11/12/2009 | 11/12/2009 | A | PASS |
Bob Reichert
|
|
|
Temp pole inspection Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe see fail
|
Application received | | | 11/11/2009 | | DONE |
|
|
|
This permit was created on the web by Rowdy Monroe
|