Final | 9/14/2010 | 9/15/2010 | 9/16/2010 | A | PASS |
Bob Reichert
|
|
|
George Phone #: ###-#### ok final
|
Permanent Service | 8/25/2010 | 8/26/2010 | 8/26/2010 | A | PASS |
Bob Reichert
|
|
|
george Phone #: ###-#### p/s u/g n ok, NOTE: contractor shall locate gec connection to concrete encased electrode for final
|
Electrical Rough-In | 6/17/2010 | 6/18/2010 | 6/18/2010 | A | PASS |
Bob Reichert
|
|
|
steve Phone #: ###-#### corrections made, ric ok
|
Electrical Rough-In | 6/16/2010 | 6/16/2010 | 6/17/2010 | P | FAIL |
Bob Reichert
|
|
|
steve Phone #: ###-#### called, left correction notice, NEC 210.52 shall add receptacles for 2' wall spacing at garage main landing, downstairs bar, living room divider,3110.4(D) sahll provide 1 1/4" protection for nm cable, 1120.26(F)(1) there shall be no foreign systems (piping) over dedicated space at panels, NOTE corrections shall be made within 5 working days or further action will be taken
|
Application received | | | 6/11/2010 | | |
|
|
|
|
Issue permit | | | 6/11/2010 | | DONE |
|
|
|
|