Permit Information
Permit NumberFIR08-00505
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 350 N MILWAUKEE ST Unit: 2060
Project NameSPR-Forever 21 Demo
Customer Number 
ePlanReview 
Description
FIR OH Work Scope:
The Fire Sprinkler scope consists of adding and relocating 172 new quick response heads to accommodate a new wall and ceiling layout in the in the Forever 21 tenant space # 2060. The fire sprinkler system work shall comply with the IFC 2006, the attached review comments/conditions, as regulated by the Fire Chief. The review comments/conditions, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. This permit is attached to BLD08-01055
To modify, as required, existing overhead sprinkler system drops to prevent damage during tenant improvements. Fire sprinkler protection shall be maintained in existing spaces during TI construction. Final head layout will be submitted under seperate fire sprinkler permit after demo phase is complete. When fire protection systems are to be temporarily put out of service, all possible work shall be accomplished in advance prior to shutting off the water to the fire sprinkler system, so that final connections can be made quickly and protection restored promptly. The chief (Fire Department) shall be notified when any required fire-protection system is out of service for over an 8-hour period and upon restoration of service.

Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/2/200810/3/200810/3/2008APASS
DetailsTroy Cobbley
Permit finaled.
INSP-Sprinkler Rough-in9/4/20089/5/20089/5/2008APASS
DetailsTroy Cobbley
The remaining fire sprinkler piping is ok to cover.
INSP-Sprinkler Rough-in9/2/20089/3/20089/3/2008APASS
DetailsTroy Cobbley
See the city approved plans for more areas where the hardlid can be installed.
INSP-Sprinkler Rough-in/Hydro8/26/20088/27/20088/27/2008APASS
DetailsTroy Cobbley
See the city approved plans where piping is ok to cover.
(F) Reprint permit  8/14/2008 DONE
CHANGE STATUS TO (ISS)  8/14/2008 DONE
PLANS/APPL TAKEN TO FRONT DESK  8/14/2008 DONE
DetailsCathy Brown
Inspection Record Card- Fire8/14/2008 8/14/2008 DONE
DetailsCathy Brown
Telephone call  8/14/2008 DONE
DetailsCathy Brown
tlk to brodie ###-#### that permit and fees are ready to be picked up
Permit Ready to Issue  8/14/2008 DONE
DetailsCathy Brown
Sprinkler Plan Check8/5/2008 8/13/2008 PASS
Details
These plans were previously approved with the condition that the contractor would resubmit the As-Built plans with the correct number of sprinkler heads affected during this TI. The total number of heads affected would appear to be 172.
Plan resubmittals received  8/5/2008  
received fire spr app. (2) pages & letter of transmittal & "5" sets of plans-- put plans on fire shelf
Issue and Print Permit  7/31/2008 DONE
Sprinkler Plan Check7/18/2008 7/18/2008 PASS
DetailsScott Arellano
PLANS/APPL TAKEN TO FRONT DESK  7/18/2008 DONE
Inspection Record Card- Fire7/18/2008 7/18/2008 DONE
Details
Telephone call  7/18/2008 DONE
Details
t/c w jeff anderson at ###-#### - permit ready and fees given
Permit Ready to Issue  7/18/2008 DONE
Details
Telephone call  7/18/2008 DONE
The following email was sent to Jeff, at TVFP 7/18/08:
Jeff,
Due to the 15,000 sf size of this space and the high occupancy load of the surrounding mall area which would be at risk by less-than-adequate sprinkler coverage, we are not comfortable with the scope of work as written on your demolition application.
We would like you to re-write the scope, deleting the sentences indicating the existing pendent sprinklers and drop piping is to be left in place until the new ceilings and walls have been constructed and heads re-installed at that time to their proper place in the new ceiling. We would like your scope to indicate that wherever the ceiling is removed, the drop piping and sprinklers will immediately be removed and upright sprinklers will be installed within the prescribed distance below the roof deck. Arm-overs are to be used wherever necessary to maintain proper head separation and spacing, as walls are removed.
Because this is a larger, operating mall, we also want to emphasize the necessity to minimize sprinkler system impairment periods and request that you keep the FD advised of which sprinkler system(s) are shut down, so the responding company will know, in case of an emergency. This should be done even though periods of impairment are not intended to exceed 8 hours.
Looking forward to receiving your revised scope.
Thanks,
Sam Rogers,
PDS/Fire Mgr
###-####
Application received  7/16/2008  
Pending Assignment by SAM7/16/2008