Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03501 ELE-Aging Inspection1/8/20071/8/20071/12/2007 4:06:09 PM DONE
called contr to see if ready for final or?
ELE00-04429 Final1/8/20071/8/20071/9/2007 2:59:33 PMPCANC
ELE06-04708 Conference1/8/20071/8/20071/8/2007 4:00:04 PMPDONE
michael H ###-#### Note: call first need 45 minutes to get to job site; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles talked about circuits, layouts, make-up, installation requirements per nec, suggested owner run a load calc with basement addition
ELE06-04020 Final1/8/20071/8/20071/8/2007 3:37:47 PMPPASS
paula, note: call first for entry code; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
ELE06-04312 Final1/8/20071/8/20071/8/2007 3:30:23 PMPPASS
NEAL; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
ELE06-04027 Electrical Rough-In1/8/20071/8/20071/8/2007 2:48:15 PMPPASS
JACK NOTE: GROUND WORK; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover u/g from house to garage only
ELE06-00109 Electrical Rough-In1/8/20071/8/20071/8/2007 2:43:24 PMPNH
Scheduled by a contractor via Hello! on 1/8/2007 at 11:00:58 AM. Contact: ###-####. callrd, left message to reschedule, left card
ELE06-04429 Permanent Service1/4/20071/8/20071/8/2007 1:32:28 PMPPASS
randy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h rec ok
ELE06-02121 Electrical Rough-In1/8/20071/8/20071/8/2007 1:17:30 PMPFAIL
LOREN; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called, left message, left corr notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A) receptacles shall be placed and spaced per 210.52(A)(1) thru (3), BCC permit shall be upgraded to 6 rooms
ELE06-02453 Electrical Rough-In1/5/20071/8/20071/8/2007 11:29:40 AMPCANC
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt Inspection cancelled from web by: Cathy Chiles
ELE07-00011 Rough-In Permanent Service1/5/20071/8/20071/8/2007 10:20:46 AMAPASS
Reinspection. Call with problems or questions. Thanks. Phone #: ###-#### x0000 corr made, ric ok, p/s o/h n ok
ELE06-04592 Electrical Rough-In1/5/20071/8/20071/8/2007 9:16:09 AMAPART
Scheduled by a contractor via Hello! on 1/5/2007 at 2:01:35 PM. Contact: ###-####. office walls and south wall only ok to cover anop
ELE07-00053 Rough-In Permanent Service1/5/20071/8/20071/8/2007 8:58:30 AMACANC
roger; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see p/s and ri
ELE07-00053 Electrical Rough-In1/8/20071/8/20071/8/2007 8:58:06 AMAFAIL
roger; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member or protected by steel plate,314.20 box shall be flush with finished surface , rear light, 334.30 nm cable shall not be stapled on edge
ELE07-00053 Permanent Service1/8/20071/8/20071/8/2007 8:55:13 AMAPASS
roger; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h n ok