ELE06-02669
| ELE-Aging Inspection | 10/18/2006 | 10/18/2006 | 10/20/2006 11:04:57 AM | | DONE |
|
|
see final
|
ELE06-01280
| ELE-Aging Inspection | 10/18/2006 | 10/18/2006 | 10/20/2006 10:56:06 AM | | PASS |
|
|
ok to final
|
ELE06-02424
| Final | 10/18/2006 | 10/18/2006 | 10/18/2006 4:00:08 PM | P | PASS |
|
|
tyler - note: call 1/2 prior to going out ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to final
|
ELE06-03742
| Electrical Rough-In | 10/18/2006 | 10/18/2006 | 10/18/2006 3:57:37 PM | P | FAIL |
|
|
randy - note: ceiling ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called left corr notice, nec 330.30(B) mc shall be strapped within 12" of box, 348.30(A) fmc shall be strapped within 12" of box, 110.12(A) unused openings in boxes shall be closed, 300.31 box covers shall be installed, BCC fixtures shall be secured in place with minimum 2 support wires, BCC no violation shall be retained
|
ELE06-02993
| Final | 10/17/2006 | 10/18/2006 | 10/18/2006 3:01:45 PM | A | PASS |
|
|
OUR CONTRACT IS COMPLETE; SOMEONE ELSE WILL HAVE TO GET A PERMIT IN FUTURE WHEN THE BUILGING AROUND POOL EQUIPMENT IS BUILT ; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack ok to final, called left message to strap rnc,
|
ELE06-03862
| Permanent Service | 10/18/2006 | 10/18/2006 | 10/18/2006 2:41:36 PM | P | PASS |
|
|
inspection on 200amp service upgrade and circuit for jetted tub and repalce exhaust fans. will be ready late this afternoon call Tate @###-#### Internet Inspection Request from: Andy Rose p/s o/h n ok
|
ELE06-03814
| Rough-In Permanent Service | 10/18/2006 | 10/18/2006 | 10/18/2006 2:16:19 PM | P | PASS |
|
|
kevin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h rec ok
|
ELE04-00305
| Final | 10/16/2006 | 10/18/2006 | 10/18/2006 1:55:05 PM | P | PASS |
|
|
chuck ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corrections made, ok to final
|
ELE06-02104
| Electrical Rough-In | 10/17/2006 | 10/18/2006 | 10/18/2006 1:26:07 PM | P | FAIL |
|
|
Mike should be on site if not please call with any questions or call Don ###-#### Thanks; Phone #: ###-#### Internet Inspection Request from: Don Lustig called, left corr notice, nec 348.30 (A) fmc shall be supported within 12" of boxes
|
ELE06-03252
| Final | 10/17/2006 | 10/18/2006 | 10/18/2006 10:58:56 AM | A | PASS |
|
|
andry; Phone #: ###-#### Internet Inspection Request from: Patricia Smith told owner to put cover plate on receptacle and move light switch for rear door, ok to final
|
ELE06-03833
| Electrical Rough-In | 10/17/2006 | 10/18/2006 | 10/18/2006 10:57:40 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Phil Baker ric ok
|
ELE06-03856
| Final | 10/17/2006 | 10/18/2006 | 10/18/2006 10:20:54 AM | A | PASS |
|
|
jessie; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to final
|
ELE06-03859
| Electrical Rough-In | 10/17/2006 | 10/18/2006 | 10/18/2006 9:46:56 AM | A | FAIL |
|
|
Call Luke the leadman if this fails inspection, Thank you!; Phone #: ###-#### Internet Inspection Request from: KATHY WEIL called, left corr notice, nec 312.5 all conductors entering enclosures shall have abrasion protection, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, BCC all make-up shall be done
|
ELE06-02811
| Final | 10/17/2006 | 10/18/2006 | 10/18/2006 9:38:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 10/17/2006 at 9:50:06 PM. Contact: ###-####. left corr notice, told owner, nec 406.8 in-use cover shall be installed outside in wet area, 406.5 faceplates shall seat against mounting surfaces, 408.4 panel cover shall be installed and circuit directory shall be complete concise and explicit, for each circuit, 422.31 disconnect shall be installed for hot water heater, 210.8(A) gfci shall operate in bath and outside, 348.30 fmc shall be securely fastened within 12" of box
|
ELE06-02178
| Electrical Rough-In | 10/17/2006 | 10/18/2006 | 10/18/2006 9:04:52 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 10/17/2006 at 11:16:22 AM. Contact: ###-####. exterior perimeter lighting only ok to cover
|
ELE06-03337
| Final | 10/17/2006 | 10/18/2006 | 10/18/2006 8:53:44 AM | A | PASS |
|
|
pat; Phone #: ###-#### note: #64 Internet Inspection Request from: Patricia Smith corr made, ok to final
|
ELE06-03628
| Final | 10/18/2006 | 10/18/2006 | 10/18/2006 8:39:20 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 10/18/2006 at 5:47:17 AM. Contact: ###-####. ok to final
|