Permit Information
Permit NumberBLD19-01753
StatusIssued
Name CM COMPANY
Site Address 720 E PARK BLVD
Project NameST. Lukes WGCP Auditorium
Customer Number 
ePlanReviewYes
Description
(ST. LUKES – WGCP - AUDITORIUM) Permit is to remodel an existing 5,514 sq. ft. auditorium. Approval is contingent upon adhering to the approved plans on file and plan review report. Work to include: removal of select portion of the auditorium stage, removal of select door/door frames, removal of select wall paneling, removal of select millwork, removal of select gypsum ceiling, construction of a new accessible stage ramp, a new raised stage platform, select wall infill, select new door/doorframes, millwork, new stage soffit, new suspended acoustic and gypsum ceiling, select new light fixtures, electrical work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered. The fire sprinkler system is used for unlimited area of the building. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Note: This building is also equipped with a smoke evacuation system that is required to be tested annually. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Letter of compliance/Occupancy  1/14/2020 DONE
BLD-Final1/10/20201/10/20201/10/2020PPASS
DetailsDave Hannah
Bruce ###-####
FIRE-Final Inspection1/10/20201/10/20201/10/2020APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work complete, signatures provided on permit sign off card.
FIRE-Conference1/9/20201/10/20201/10/2020ADONE
DetailsJim Page
Fire conference complete.

Bruce Phone #: ###-####
BLD-Final9/26/20199/27/20199/27/2019PPASS
DetailsTony Young
Mike Phone #: ###-####,,occupancy ok pending others
BLD-Final9/26/20199/26/20199/26/2019PCANC
DetailsTell Riley
Bruce Phone #: ###-####
BLD-Final9/24/20199/26/20199/26/2019ANR
DetailsTell Riley
Bruce Phone #: ###-####//need mechanical final completed prior to occupancy//
FIRE-Final Inspection9/24/20199/26/20199/26/2019APART
DetailsJim Page
Partial final inspection for life fire safety in area of work complete, fire alalrm modifications are part of the main head unit replacement on the fire alarm system (FIR19-00066), FIR permit has not been finaled, fire alarms in area of work are functional and code compliant, fire sprinkler inspection is complete, fire extinguishers are placed with current inspection tags. TCO authorized for 45 days contingent on fire alarm permit being completed. This permit holder will need to request a final life fire safety inspection to complete this permit after FIR19-00066 is finaled.

Bruce Phone #: ###-####
BLD-Final9/24/20199/25/20199/25/2019ACANC
DetailsDave Hannah
Bruce Phone #: ###-####
FIRE-Final Inspection9/24/20199/24/20199/24/2019PCANC
DetailsJim Page
Bruce Phone #: ###-####
BLD-Wall Bracing8/22/20198/23/20198/23/2019APART
DetailsDave Hannah
Bruce Phone #: ###-#### framing for stage ok to cover
BLD-Ceiling Grid Inspection8/13/20198/13/20198/13/2019PPASS
DetailsTell Riley
Bruce Phone #: ###-####//grid ok to cover//all trades rough ins passed//
BLD-Framing/Rough-in7/16/20197/17/20197/17/2019APART
DetailsDave Hannah
Bruce Phone #: ###-#### soffit above stage and av wall ok
Inspection Record Card- Bld  6/13/2019 DONE
Issue PAID IN FULL permit  6/13/2019 DONE
Plan assigned to (JG)5/20/20195/20/20196/10/2019 PASS
DetailsJavier Guzman
2nd rev comp, 05/31 L2 WGCP Auditorium ePlan
Routing - PLAN CHECK6/3/2019 6/10/2019 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  6/10/2019 DONE
Permit Ready to Issue  6/10/2019 DONE
ALL MET: seans@cmcompany.com

Need GC
Need rev cert of val
Route to Impact Fee Review5/31/20196/3/20195/31/2019 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE5/20/20195/20/20195/31/2019 PASS
DetailsMark Scharfen
05/31 Completed IFC review. Uploaded rev_fire 05.31.2019.pdf. Passed review.
Routing - PLAN CHECK5/20/2019 5/31/2019 FAIL
DetailsJavier Guzman
1st review completed  5/31/2019 FAIL
Details
Routing - MECHANICAL5/20/2019 5/24/2019 PASS
DetailsTroy James
Intake Approval  5/20/2019 PASS
DetailsJavier Guzman
Application received  5/15/2019 DONE
Application submitted via PDS Online on May 15 2019 4:22PM