Information based on query as of Saturday, May 18, 2024.
Permit Information
Permit NumberBLD17-03282
StatusFinaled
Name PRUSIK CONSTRUCTION
Site Address 9964 W OVERLAND RD
Project NameUnion Square - Corner Building
Customer Number 
ePlanReviewYes
Description
UNION SQUARE (Cold Shell Only) To construct a 5,190 sq. ft. one story cold shell commercial building and related site improvements for future use as a restaurant/office/retail business. Scope of work includes: construction of concrete foundation, stud framed exterior walls with stucco, stone veneer finish, pre-engineered wood truss roof system and roofing. This is a shell permit only and no occupancy is allowed under this permit. A separate tenant improvement permit is required for occupancy. All work shall comply with the approved plans, DRH17-00311 and all applicable codes. Note: The shell building constructed as a cold shell specifically indicating no wall/attic insulation was installed under this shell permit, Envelope compliance report approved for Slab edge and openings only. This building is Not Fire Sprinklered **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/3/201812/3/201812/3/2018PPASS
DetailsMike Jordan
Building shell final, plumbers are calling in to close out their permits this morning.
Thank you Michael McHargue Phone #: ###-#### Inspection requested via web by Michael McHargue
DOC - Permit Finaled12/3/201812/3/201812/3/2018PPASS
DetailsMike Jordan
FIRE-Final Inspection11/30/201811/30/201811/30/2018PPASS
DetailsTroy Cobbley
Life safety passed

Adam Phone #: ###-####
BLD-Framing/Rough-in10/18/201810/18/201810/18/2018PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Adam Joslin
BLD-Wall Bracing8/28/20188/28/20188/28/2018PPASS
DetailsMike Jordan
shear // Adam Phone #: ###-####. All issues have been corrected.
BLD-Wall Bracing8/27/20188/27/20188/27/2018PFAIL
DetailsMike Jordan
Adam Phone #: ###-####. Shear wall type 2 needs either 8d nails or 15 guage staples for atachment min. Appears that 16 guage was used.
BLD-Other8/10/20188/13/20188/13/2018APASS
DetailsMike Jordan
roof shear // Adam Phone #: ###-####. Roof diaprtagm nailing and hardware ok.
BLD-Other6/21/20186/22/20186/22/2018ACANC
DetailsMike Jordan
Alex-roof drain Phone #: ###-####
BLD-Foundation6/15/20186/15/20186/15/2018PCANC
DetailsMike Jordan
Adam Phone #: ###-####
BLD-Energy code compliance6/15/20186/15/20186/15/2018PPASS
DetailsMike Jordan
Adam Phone #: ###-####. Rigid insulation at interior side of stemwall ok.
BLD-Foundation6/11/20186/12/20186/12/2018APASS
DetailsMike Jordan
Dane Phone #: ###-####
BLD-Foundation6/8/20186/11/20186/11/2018PPASS
DetailsMike Jordan
Dane Phone #: ###-####
BLD-Footing6/7/20186/8/20186/8/2018PPASS
DetailsMike Jordan
Dane Phone #: ###-####