Information based on query as of Sunday, May 19, 2024.
Permit Information
Permit NumberBLD18-00919
StatusFinaled
Name WRIGHT BROTHERS THE BLDG CO EAGLE
Site Address 1100 S FIVE MILE RD
Project NameFive Mile Storage-Building A-1
Customer NumberBLD18-00795-00800, BLD18-00919-0021
ePlanReview 
Description
(FIVE MILE STORAGE – BUILDING #A-1) (10 PERMITS FILED UNDER BLD18-00685 IN EPLAN REVIEW THESE BLD’S ARE BLD18-00795-00800, and BLD18-00919-00921) NOTE: This building has a 3-hour fire barrier wall to separate the buildings A/A-1/A-2 into different fire areas. Permit to construct a new 5,928 sq. ft. storage building (19 storage units) and related site improvements. Scope of work includes: construction of a slab on grade concrete, concrete foundation, construction of steel stud framed exterior walls with metal siding, metal roof purlins with a metal roof, metal storage unit partition panels, installation of new overhead doors, new electrical and site work. The building is not fire sprinklered. Note: Special Inspections Required see form 310. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/18/201810/19/201810/19/2018PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by KJ Savaria
FIRE-Final Inspection10/17/201810/18/201810/18/2018PPASS
DetailsTroy Cobbley
Life safety passed. The Opticon was tested by Station 14. Plan review is ok with the 4'-9" access to man gates.


Phone #: ###-#### Inspection requested via web by KJ Savaria
BLD-Other10/2/201810/2/201810/2/2018PPASS
DetailsMike Jordan
Final layer with fire tape for the Firewall Phone #: ###-#### Inspection requested via web by KJ Savaria
BLD-Other9/17/20189/18/20189/18/2018APASS
DetailsMike Jordan
2nd layer of drywall for 3 HR Firewall Phone #: ###-#### Inspection requested via web by KJ Savaria
BLD-Wall cover9/12/20189/13/20189/13/2018AFAIL
DetailsMike Jordan
First layer of drywall on 3-Hour rated fire separation wall. Phone #: ###-#### Inspection requested via web by KJ Savaria. Needs to follow the approved UL design on approved plans or provide another approved 3hr. rated fire barrier assembly for the in place base layer.
BLD-Footing6/14/20186/15/20186/15/2018APART
DetailsMike Jordan
Casey-pour time 11:00 Phone #: ###-####. Reinforcement is tied, needs to placed in footing excavation. Ok to place concrete pending special inspection.