Information based on query as of Friday, June 14, 2024.
Permit Information
Permit NumberBLD18-02779
StatusFinaled
Name JAYO CONSTRUCTION INC
Site Address 411 W SAND DUNE LN
Project NameL26B1
Customer Number 
ePlanReviewNo
Description
***Fire sprinklers are required***Precriptive component energy approach***WUI Zone A requirements*** Permit for the construction of a new 2,501 sq. ft., two story (first story 2,231 sq. ft., below grade 270 sq. ft.) single family dwelling with 3 bedrooms, 2 bathrooms, approximately 300 sq. ft. of covered patio/porch and a 865 sq. ft. attached garage per the approved plans and any notations. R-1B zoning and setbacks per planning. MDHA letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/18/20205/18/20205/18/2020PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by SHANE JAYO
DOC - Permit Finaled5/18/20205/18/20205/18/2020PPASS
DetailsBrandon Shaw
BLD-Final5/14/20205/15/20205/15/2020AFAIL
DetailsBrandon Shaw
Need PW approval...
R311.7.5.1 open riser are permitted... provided the passage of a 4" sphere is not permitted...
R314.3 Smoke alarms... immediate vicinity of the bedroom, and each story...
BLD-Blower Door Test Results5/15/20205/15/20205/15/2020ADONE
DetailsBrandon Shaw
ACH50- 6.58
BLD-Grading Inspection5/14/20205/14/20205/14/2020PCANC
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by SHANE JAYO
BLD-Aging Inspection1/10/20201/10/20201/10/2020 DEFR
DetailsBrandon Shaw
Extend Permit 90/180 days1/10/20201/10/20201/10/2020PDONE
DetailsBrandon Shaw
BLD-Framing/Rough-in8/27/20198/29/20198/29/2019APASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by SHANE JAYO
BLD-Framing/Rough-in8/26/20198/27/20198/27/2019PCANC
DetailsBrandon Shaw
Phone #: ###-#### >> Inspection requested via web by SHANE JAYO Inspection cancelled from web by: SHANE JAYO
BLD-Energy code compliance8/20/20198/21/20198/21/2019AFAIL
DetailsBrandon Shaw
Previous corrections not complete-
4x8 header, ais seal, and fire caulking...
Per shear pg 7 of 13- Balloon wall to be 2x6 12" o.c....
Need sprinkler trenting approval...
BLD-Framing/Rough-in7/31/20198/1/20198/1/2019APART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by SHANE JAYO,, ok to insulate,, needs fire blocking, finish fur downs, justify attic venting,, add header at stair landing area,, see painted notes,, will need one more sprinkler inspection
BLD-Wall Bracing7/26/20197/26/20197/26/2019PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by SHANE JAYO
BLD-Wall Bracing7/25/20197/26/20197/26/2019ADEFR
DetailsTony Young
Phone #: ###-#### Inspection requested via web by SHANE JAYO
BLD-Framing/Rough-in7/25/20197/25/20197/25/2019PFAIL
DetailsBrandon Shaw
No air/foam seal...
No Sprinkler ruogh-in...
BLD-Other7/23/20197/24/20197/24/2019APASS
DetailsDave Hannah
Need Sheetrock on soffits inspected Phone #: ###-#### Inspection requested via web by SHANE JAYO
BLD-Framing/Rough-in7/23/20197/24/20197/24/2019ACANC
DetailsDave Hannah
Phone #: ###-#### >> Inspection requested via web by SHANE JAYO Inspection cancelled from web by: SHANE JAYO
BLD-Foundation4/2/20194/2/20194/2/2019PPART
DetailsTony Young
Bill Phone #: ###-####,, work in progress
BLD-Footing3/26/20193/27/20193/28/2019PDONE
DetailsTony Young
Phone #: ###-#### Inspection requested via web by SHANE JAYO
BLD-Footing3/27/20193/28/20193/28/2019APART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by SHANE JAYO,, work in progress