Information based on query as of Thursday, May 16, 2024.
Permit Information
Permit NumberBLD18-03791
StatusFinaled
Name DOUBLE L CONSTRUCTION LLC
Site Address 92 S COLE RD
Project NameCenter for Behavioral Health
Customer Number 
ePlanReviewYes
Description
(CENTER FOR BEHAVIORAL HEALTH - FRANKLIN BUSINESS PARK - BLDG 2) Permit is to combine an existing 2,028 sq. ft. business space with the adjacent 547 sq. ft. tenant space to create a new tenant space that is 2,575 sq. ft. within the 14,421 sq. ft. existing building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frame, construction of select interior non-bearing walls to create (2) offices, (2) storage rooms and a hallway, select new light fixtures, electrical work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/8/20194/9/20194/9/2019APASS
DetailsMike Jordan
Lloyd Phone #: ###-####. OK for perm occ.
FIRE-Final Inspection4/9/20194/9/20194/9/2019APASS
DetailsMike Jordan
Lloyd Phone #: ###-####. All issues have been resolved.
BLD-Final4/4/20194/5/20194/5/2019PNR
DetailsMike Jordan
Call 30 minutes ahead // Lloyd Phone #: ###-####
FIRE-Final Inspection4/4/20194/5/20194/5/2019AFAIL
DetailsMark Scharfen
Conducted fire life safety inspection.
Existing office door hardware needs to be changed to latch (they currently are round).Rear door e-light failed. Missing exit sign in hall (had paper placard on wall at end of hall). Rear door is a double door. One door has crash bar, 2nd door has flush slide bolts to keep door closed. After talking with Carl Madsen about storage double doors, the flush bolt is ok because of there not being any door hardware on the inoperable door. Sent a text to Lloyd.


Call 30 minutes ahead // Lloyd Phone #: ###-####
BLD-Final3/28/20193/29/20193/29/2019PCANC
DetailsMike Jordan
Lloyd Phone #: ###-####
FIRE-Final Inspection3/28/20193/29/20193/29/2019ACANC
DetailsTroy Cobbley
Lloyd Phone #: ###-####
BLD-Framing/Rough-in2/5/20192/6/20192/6/2019APASS
DetailsMike Jordan
Loyd Phone #: ###-####. Interior wood framed walls ok.