Permit Information
Permit NumberBLD18-03971
StatusFinaled
Name BRIGHT STAR ENERGY MANAGEMENT LLC
Site Address 5685 N COLLISTER DR
Project Name5685 Collister House
Customer NumberDEMO BLD07-01989
ePlanReviewYes
Description
***Passes using UA trade off method R38 in the floor*** WUI Zone A requirements*** Permit for the construction of a new 2785 sq. ft., two story (first story 1145 sq. ft., second story 1640 sq. ft.) single family dwelling with 5 bedrooms, 3 bathrooms, approximately 40 sq. ft. of covered patio/porch and a 810 sq. ft. attached garage per the approved plans and any notations. R1-B zoning and setbacks per planning. MDH SPRINKLERS ARE NOT REQUIRED. LGM
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/20/20203/20/20203/20/2020PPASS
DetailsMike Jordan
energy cert notice posted on breaker box door.

handrails have been raised Phone #: ###-#### Inspection requested via web by Stephen Griswold. All issues were resolved.
BLD-Blower Door Test Results3/20/20203/20/20203/20/2020PDONE
DetailsMike Jordan
4.3
BLD-Final3/19/20203/19/20203/19/2020PFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Stephen Griswold. Exterior handrail to main entry mounted to low. provide blower door test results and report as well as the required energy cert and post. Correction notice posted.
BLD-Aging Inspection1/21/20201/21/20201/22/2020 PEND
DetailsTony Young
BLD-Final1/17/20201/17/20201/17/2020PNR
DetailsTony Young
Please call with an estimated ETA for inspection, I''d like to be there. Phone #: ###-#### Inspection requested via web by Stephen Griswold// needs hillside,, trades,, hand rails per code,, blower door test,, fire caulking,, address, etc
BLD-Framing/Rough-in9/9/20199/9/20199/9/2019PPASS
DetailsJim Storey
Please call 30 minutes before arrival. We would like to meet with inspector on site. Phone #: ###-#### Inspection requested via web by Stephen Griswold
BLD-Energy code compliance9/9/20199/9/20199/9/2019PPASS
DetailsJim Storey
Please call 30 minutes before arrival. We would like to meet with inspector on site. Phone #: ###-#### Inspection requested via web by Stephen Griswold
BLD-Framing/Rough-in8/28/20198/28/20198/28/2019PPART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Stephen Griswold,, see painted corrections,, seal plates, need truss engineering, strap plates, etc,, ok to insulate
BLD-Foundation5/20/20195/21/20195/21/2019ADONE
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Andrew Clark
BLD-Footing5/20/20195/20/20195/20/2019PPART
DetailsTony Young
Andrew- wall footing Phone #: ###-####,, footings already done,, foundation wall ok
BLD-Footing5/16/20195/17/20195/17/2019APASS
DetailsBrandon Shaw
Work in progress...
BLD-Conference5/15/20195/15/20195/15/2019PPART
DetailsTony Young
Andrew Phone #: ###-####,, foundation ?s,, needs to be 24" frost protection,, can use existing retaining wall footing to support the first couple of floor joists with proper sill and attachment
BLD-Footing4/30/20195/2/20195/2/2019PCANC
DetailsTony Young
Jared Phone #: ###-#### cancel per jared