Permit Information
Permit NumberBLD19-00591
StatusFinaled
Name STEED CONSTRUCTION
Site Address 7960 W RIFLEMAN ST Unit: STE 110
Project NameArtisan Pediatric Eyecare
Customer Number 
ePlanReviewYes
Description
(ARTISAN PEDIATRIC EYECARE – TOWN SQUARE STATION BUILDING “B”) Permit for tenant improvements to an existing 6,974 sq. ft. tenant space previously occupied by Toy Town for a new medical office. Work to include: demolition of portions of exterior wall, existing interior non-bearing walls, doors, and plumbing; relocating exterior storefront doors and installing new windows; new interior non-bearing partition walls and doors; new gypsum board and suspended ACT ceilings; new accessible single user restrooms; electrical power and lighting; new mechanical RTU, exhaust fans, mini-split units, and ductwork; new plumbing work; and interior finishes in compliance with 2015 IBC Ch. 8. Special inspections required per the attached Form 310. This building has a fire sprinkler system used for building area increase and for story increase. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/22/201911/25/201911/25/2019APASS
DetailsMike Jordan
Mike Phone #: ###-####. Ok for perm occ.
BLD-Final8/1/20198/2/20198/2/2019APART
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. Ok for temp occ. ok to see clients. Needs to provide ADA compliant counter at main check in desk.
BLD-Final7/25/20197/26/20197/26/2019PPART
DetailsTell Riley
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman//temp occupancy to move in equipment//no patient exams until final occupancy//
FIRE-Final Inspection7/25/20197/26/20197/26/2019PPASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work complete.

Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman
BLD-Ceiling Grid Inspection6/20/20196/20/20196/20/2019PPASS
DetailsMike Jordan
Early afternoon Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman
BLD-Ceiling Grid Inspection6/19/20196/19/20196/19/2019PFAIL
DetailsMike Jordan
provide means of keeping main and cross runners from spreading.
BLD-Ceiling Grid Inspection6/18/20196/19/20196/19/2019ANR
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. Mech inspection above grid has failed.
BLD-Framing/Rough-in4/26/20194/26/20194/26/2019PPASS
DetailsMike Jordan
Jim Phone #: ###-####. Interior steel stud framed walls,hardlids and soffits only.