Permit Information
Permit NumberBLD19-03779
StatusFinaled
Name MONTANDON BUILDING LLC
Site Address 242 N 8TH ST Unit: STE 210
Project NameFidelity Building: source T.I.
Customer Number 
ePlanReviewYes
Description
(SOURCE MEDITATION - Fidelity building Suite #210) Permit to remodel an existing 730 sqft office suite for meditation space. Work to include: Demo of finishes and interior non load bearing walls, construct new 8'-0" partition wall and install new finishes. Approval is contingent on adhering to the approved plans and local codes and ordinances. Interior finishes shall be in compliance with Ch. 8 of the 2015 IBC. This building is fully fire sprinkled. Any alterations or modifications to the buildings fire sprinkler or fire alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise fire department. MDH
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/27/20205/28/20205/28/2020APASS
DetailsBrandon Shaw
screened // Paul Phone #: ###-####
DOC - Permit Finaled5/28/20205/28/20205/28/2020PPASS
DetailsBrandon Shaw
BLD-Final5/14/20205/15/20205/15/2020PPART
DetailsMike Jordan
Paul Phone #: ###-####. Ok for temp occ. Needs to provide ADA POS.
FIRE-Final Inspection5/13/20205/14/20205/14/2020APASS
DetailsJim Page
Previously noted items have been corrected, curtian that was causing fire sprinkler blockage has been removed, no fire sprinkler modifications, no fire alarm modifications, fire extinguishers are in common areas with current inspection tags. Final life fire safety inspection is complete, signatures provided on permit sign off card.

Paul *screened* Phone #: ###-####
FIRE-Final Inspection3/9/20203/10/20203/10/2020AFAIL
DetailsJim Page
Fire sprinkler modifications are required in area of work, fire sprinkler modifications will reuqire a seperate permit. Entry door hardware does not comply with 1010.1.9.1 of the 2015 International Fire Code. Provide annual inspection on fire extinguishers and wall mount fire extinguishers as discussed, extinguishers are not to be placed on the floor per code requirements, extinguisher must be mounted, not less than 4 inches off of the floor and not more than 48 inches to extinguisher mechanism.

Paul- please call for access Phone #: ###-####
FIRE-Final Inspection3/4/20203/6/20203/6/2020AFAIL
DetailsJim Page
Could not access space due to being locked, provide code compliant door hardware on main entry.

Paul Phone #: ###-####
BLD-Final3/2/20203/4/20203/4/2020ANR
DetailsBrandon Shaw
Need Fire/life...