Permit NumberBLD20-00481
StatusIssued
Name LEVCO BUILDERS LLC
Site Address 2032 S DENELL WAY
Project NameKaae addition
Customer Number 
ePlanReviewNo
Description
Permit for a remodel, to include: 650 sq ft. (10'X65') addition at back of home, also includes covered patio. Reconfiguring existing kitchen area to be new pantry. Addition makes master bedroom larger and adds master closet and laundry area and kitchen. Also includes masterbath remodel. - All work per plans, notations, attachments, engineering, local codes & ordinances. Separate electrical, plumbing & mechanical permits required. JJN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Framing/Rough-in4/21/20204/22/20204/22/2020APASS
DetailsMike Jordan
screened - building vacant // Noah Phone #: ###-####
BLD-Energy code compliance4/22/20204/22/20204/22/2020APASS
DetailsMike Jordan
screened - building vacant // Noah Phone #: ###-####
BLD-Framing/Rough-in4/16/20204/16/20204/16/2020PFAIL
DetailsMike Jordan
Screened- house is vacant -Noah Phone #: ###-####. Needs to provide engineering fix for insufficient bearing on G1 truss and install bearing blocks as shown on truss engeering on G1 and G2 truss.
BLD-Framing/Rough-in4/14/20204/14/20204/14/2020PFAIL
DetailsMike Jordan
Screened- home is vacant- virtual inspection ok- Noah Phone #: ###-####. Provide truss engineering. Strap double top plate breaks from addition to existing. 3 ply G02 truss, plys not in contact. Appears to be insufficient bearing on 6x6 G01 truss. Need truss engineering to verify.. Correction notice posted. Ok to insulate.
BLD-Framing/Rough-in4/9/20204/10/20204/10/2020ANR
DetailsMike Jordan
screened // Noah Phone #: ###-####. Mech. rough in inspection required prior to framing inspection.
BLD-Wall Bracing3/16/20203/17/20203/17/2020APASS
DetailsMike Jordan
Noa Phone #: ###-####
BLD-Wall Bracing3/12/20203/12/20203/12/2020PDONE
DetailsMike Jordan
noah - partial shear for the roof Phone #: ###-####
BLD-Footing3/5/20203/5/20203/5/2020PPASS
DetailsMike Jordan
Noa Phone #: ###-####. Column pad footings for patio cover.
BLD-Foundation2/19/20202/20/20202/20/2020APART
DetailsMike Jordan
Gadi Phone #: ###-####
BLD-Footing2/19/20202/19/20202/19/2020PPASS
DetailsMike Jordan
BLD-Footing2/18/20202/19/20202/19/2020AFAIL
DetailsMike Jordan
Gali Phone #: ###-####. Footings to be 12 inch deep min. per enginering. Also noted footing subgrade is frozen.