Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberBLD20-00821
StatusFinaled
Name HAYDEN HOMES IDAHO LLC
Site Address 6797 S SILVER SPUR WAY
Project NameBaserri
Customer Number 
ePlanReviewYes
Description
**PASSES USING UA TRADE-OFF**Permit for the construction of a new 1800 sq. ft., one story Single Family Dwelling Unit with 3 bedrooms, 2 bathrooms, approximately 274 sq. ft. of covered patio/porch and a 796 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. **D_S**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/30/20206/30/20206/30/2020APASS
DetailsMike Jordan
Call or text for access Phone #: ###-#### Inspection requested via web by Allen Jones
DOC - Permit Finaled6/30/20206/30/20206/30/2020PPASS
DetailsMike Jordan
BLD-Energy code compliance5/6/20205/6/20205/6/2020PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Allen Jones
BLD-Framing/Rough-in5/4/20205/4/20205/4/2020PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Allen Jones
BLD-Wall Bracing4/9/20204/14/20204/14/2020PPASS
DetailsDave Hannah
screened // Zane Phone #: ###-####
BLD-Foundation3/26/20203/27/20203/27/2020APART
DetailsMike Jordan
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell. Noted that stemwall placement does not met the projection in some areas. Will need to dowel footing and provide addtional footing .
BLD-Footing3/24/20203/24/20203/24/2020PPASS
DetailsMike Jordan
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
BLD-Footing3/23/20203/24/20203/24/2020AFAIL
DetailsMike Jordan
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell . Repairs not yet completed.
BLD-Footing3/23/20203/23/20203/23/2020AFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Allen Jones. Interior type C column not correct size and rebar mat incorrect. Type C and both type A columns at garage not sized correctly and missing rebar.