Permit Information
Permit NumberELE18-01730
StatusFinaled
Name SUBLIME ELECTRIC LLC
Site Address 1724 E WARM SPRINGS AVE
Project Name 
Customer NumberRMR
ePlanReviewNo
Description
Alteration or Repair: Wire for new service and remodel
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/19/20192/20/20192/20/2019APASS
DetailsJames Ady
Call Dominic to meet you ###-####. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Corrections made final ok
Final2/12/20192/13/20192/12/2019ACANC
DetailsJames Ady
Call Dominic ###-#### on your way to meet you there. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### >> Inspection requested via web by Clayton Morgan Inspection cancelled from web by: Clayton Morgan
Final2/12/20192/13/20192/12/2019ACANC
DetailsRock A. Hudson
Please call Ryan ###-#### and he will be there or meet you there. If you have any questions please feel free to contact Darren ###-####. Thanks!!! Phone #: ###-#### >> Inspection requested via web by Clayton Morgan Inspection cancelled from web by: Clayton Morgan
Final2/7/20192/8/20192/8/2019AFAIL
DetailsRock A. Hudson
Please call Dominic ###-#### to meet you there. If you have any questions please feel free to contact Darren ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan
210.8- All 15 and 20 amp 120 volt receptacle outlets located in a garage shall have GFCI protection. Vac.
210.52(C)(5)- Receptacles installed to serve kitchen counter top areas shall be locagted not more than 20" above counter.
314.16- In ADU receptacle located in end of peninsula shall have a box installed with adequate cubic inch capacity for wiring and device.
314.25- All boxes shall have covers. Front entry to right of front door. Closets shall be blanked or have luminaire installed as per 410.16.
BCC 4-05-24- Inspection required for UF underground to feed post light. Date on wire is new and incomplete.
Electrical Rough-In10/4/201810/5/201810/5/2018APASS
DetailsJames Ady
Please call Luke for access ###-####. Thank You!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Corrections made rough in ok
Electrical Rough-In10/3/201810/4/201810/4/2018AFAIL
DetailsJames Ady
There will be someone there. If you have any questions please feel free to contact Darren ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 210.52D Bathroom recep shall be on adjacent wall to sink basin.
Rough-In Permanent Service8/13/20188/14/20188/14/2018APASS
DetailsJames Ady
It will be open. If you have any questions please feel free to contact Tony ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Addition only ok to cover. DO NOT cover entry patio. Service calc needed for addition.