Final | 2/19/2019 | 2/20/2019 | 2/20/2019 | A | PASS |
James Ady
|
|
|
Call Dominic to meet you ###-####. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Corrections made final ok
|
Final | 2/12/2019 | 2/13/2019 | 2/12/2019 | A | CANC |
James Ady
|
|
|
Call Dominic ###-#### on your way to meet you there. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### >> Inspection requested via web by Clayton Morgan Inspection cancelled from web by: Clayton Morgan
|
Final | 2/12/2019 | 2/13/2019 | 2/12/2019 | A | CANC |
Rock A. Hudson
|
|
|
Please call Ryan ###-#### and he will be there or meet you there. If you have any questions please feel free to contact Darren ###-####. Thanks!!! Phone #: ###-#### >> Inspection requested via web by Clayton Morgan Inspection cancelled from web by: Clayton Morgan
|
Final | 2/7/2019 | 2/8/2019 | 2/8/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Please call Dominic ###-#### to meet you there. If you have any questions please feel free to contact Darren ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 210.8- All 15 and 20 amp 120 volt receptacle outlets located in a garage shall have GFCI protection. Vac. 210.52(C)(5)- Receptacles installed to serve kitchen counter top areas shall be locagted not more than 20" above counter. 314.16- In ADU receptacle located in end of peninsula shall have a box installed with adequate cubic inch capacity for wiring and device. 314.25- All boxes shall have covers. Front entry to right of front door. Closets shall be blanked or have luminaire installed as per 410.16. BCC 4-05-24- Inspection required for UF underground to feed post light. Date on wire is new and incomplete.
|
Electrical Rough-In | 10/4/2018 | 10/5/2018 | 10/5/2018 | A | PASS |
James Ady
|
|
|
Please call Luke for access ###-####. Thank You!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Corrections made rough in ok
|
Electrical Rough-In | 10/3/2018 | 10/4/2018 | 10/4/2018 | A | FAIL |
James Ady
|
|
|
There will be someone there. If you have any questions please feel free to contact Darren ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 210.52D Bathroom recep shall be on adjacent wall to sink basin.
|
Rough-In Permanent Service | 8/13/2018 | 8/14/2018 | 8/14/2018 | A | PASS |
James Ady
|
|
|
It will be open. If you have any questions please feel free to contact Tony ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Addition only ok to cover. DO NOT cover entry patio. Service calc needed for addition.
|