Final | 8/15/2019 | 8/16/2019 | 8/16/2019 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
Permanent Service | 7/16/2019 | 7/16/2019 | 7/16/2019 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk p/s o/h rec ok
|
Final | 2/15/2019 | 2/20/2019 | 2/20/2019 | P | PART |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk 110.8, 11,27(B), 300.3(A)- Exposed conductors running in and out of meter bases shall be installed in a recognized wiring method of chapter 3. 230.70(A)(1)- Main disconnecting means of service shall be on exterior of building or immediately on inside. BCC 4 05 31(C)- Unfused conductors shall not enter a structure unless underground fed with a max of 4 1/2' in length. 240.24- Over current devices shall not be installed over stairs. Service reconnect was granted on temporary basis so other tenants would not be without power for an extended period of time. 60 amp feeds to each apartment ok to remain if no changes done to apartments. Complete service change is required. Unit 4 tested ok. TCO ok
|
Final | 1/31/2019 | 1/31/2019 | 1/31/2019 | P | NH |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk All areas locked. Unit 4 looks lived in. Reschedule when accessible.
|
Electrical Rough-In | 7/16/2018 | 7/16/2018 | 7/16/2018 | P | PASS |
Rock A. Hudson
|
|
|
Only a few walls opened up in kitchen only. Rough in ok cover
|
Electrical Rough-In | 7/16/2018 | 7/16/2018 | 7/16/2018 | P | FAIL |
Rock A. Hudson
|
|
|
Unit #4 - Code 0140 Phone #: ###-#### Inspection requested via web by Alan Lusk Lock box on rail on exterior, not sure which unit is unit 4. Have door identified and recall.
|
Permanent Service | 5/23/2018 | 5/23/2018 | 5/23/2018 | P | PASS |
Rock A. Hudson
|
|
|
Service was damage from fire. installed new grounding system. Phone #: ###-#### Inspection requested via web by Alan Lusk Approved on temporary basis until such time is provided to complete a service change. Damaged unit not energized. p/s o/h rec ok
|