Final | 4/25/2019 | 4/26/2019 | 4/26/2019 | A | PASS |
Eric Story
|
|
|
GARAGE CODE 7573 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
Electrical Rough-In | 3/15/2019 | 3/15/2019 | 3/15/2019 | A | PASS |
Eric Story
|
|
|
Floor heat master bathroom, garage code is 7573. Please contact Bob with any questions. Thank! Phone #: ###-#### Inspection requested via web by Bob Glenn Floor heat ok to cover
|
Rough-In Permanent Service | 1/17/2019 | 1/18/2019 | 1/18/2019 | A | PASS |
James Ady
|
|
|
corrections made, ceiling furred down, call mike for any questions Phone #: ###-#### Inspection requested via web by Bob Glenn corrections made rouhgh in ok p/s u/g n ok
|
Rough-In Permanent Service | 1/16/2019 | 1/16/2019 | 1/16/2019 | P | FAIL |
Rock A. Hudson
|
|
|
The ceiling in the bottom of the garage stairs will be furred down so its flat, we have 2 can lights and a smoke detector/ CO2 combo going in there when the fur down is done Phone #: ###-#### Inspection requested via web by Bob Glenn 210.52(A)- In habitable rooms no point measured along floor line shall be more than 6' from a receptacle outlet. Up rec room 13' between receptacle outlets. 300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Top of house stair in be at floor level marked with X and at bottom of house stair above switches where drill at 45 degree angle.
|