Information based on query as of Tuesday, May 14, 2024.
Permit Information
Permit NumberELE19-01417
StatusIssued
Name NICHOLS TROY M
Site Address 2623 S LEADVILLE AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Replace panel, update wiring, update outlet and lighting fixtures.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Electrical Rough-In5/14/20195/14/20195/14/2019PPASS
DetailsJames Ady
Re-inspection of kitchen. Please call or text prior, thank you. Phone #: ###-#### Inspection requested via web by Troy Nichols Corrections made kitchen rough in ok
Electrical Rough-In5/9/20195/10/20195/10/2019PPASS
DetailsJames Ady
Please text or call prior to arrival, thank you. Phone #: ###-#### Inspection requested via web by Troy Nichols Need to add circuit for range hood, Add 2nd small appl. circuit and seperate counter top rreceps, Need deeper boxes for cooktop and double oven, Remove disp. from small appl. circuit and feed from dish. circuit. Do Not Cover Kitchen. Dining, sun and living rooms ok to cover
Conference4/28/20194/29/20194/29/2019ADONE
DetailsRock A. Hudson
Conference on fixtures and removal of old knob and tube wiring. Phone #: ###-#### Inspection requested via web by Troy Nichols
Pamphlet given, discussed receptacle layout for habitable rooms and kitchen counter top areas. Removing all knob and tube and rewiring all level 1.
Permanent Service4/26/20194/26/20194/26/2019PPASS
DetailsRock A. Hudson
Owner to replace grounding electrode to underground water pipe with #4 ground as per 250.66 and secure panel to wall better.
p/s o/h rec ok
Permanent Service4/25/20194/26/20194/25/2019ACANC
DetailsJames Ady
Phone #: ###-#### >> Inspection requested via web by Troy Nichols Inspection cancelled from web by: Troy Nichols
Conference4/19/20194/22/20194/22/2019APASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Troy Nichols talked about grounding, Feeder conductor size, Weather head, when to call for inspection. Also informed owner to call ID power to schedule disc. amd reconnect.