Final | 10/2/2019 | 10/3/2019 | 10/3/2019 | A | PASS |
Eric Story
|
|
|
Lock box code 1965 by gas meterr Phone #: ###-#### Inspection requested via web by Hidajet Zahic Corrections fixed final ok
|
Final | 10/2/2019 | 10/2/2019 | 10/2/2019 | P | FAIL |
Eric Story
|
|
|
Lock box code 1965 Phone #: ###-#### Inspection requested via web by Hidajet Zahic 334 Type NM cable shall not be used in a wet location 406 All 120V recetpacles shall be tamper resistant
|
Electrical Rough-In | 8/13/2019 | 8/13/2019 | 8/13/2019 | P | PASS |
Rock A. Hudson
|
|
|
Underground to well confirmed direct burial approved, Found label under well head. Rough in ok cover
|
Rough-In Permanent Service | 8/12/2019 | 8/12/2019 | 8/12/2019 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic A inspection is required for underground to well. Provide documentation on underground wire used. Appears to be standard 8-3 NM cable. Tried to call contact, unable to connect. Underground to service not in at time of inspection. House rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 8/11/2019 | 8/12/2019 | 8/12/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic 330.30- Mini split MC cables shall be supported so that no point exceeds 6'. North wall mostly. 1 hanging below trusses. 334.30- NM cables shall be secured with in 12" of boxes and supports not to exceed 4 1/2'. AC has no support, entry switch above box, bed switch above box, disposal wiring taken apart.
|
Rough-In Permanent Service | 7/30/2019 | 7/31/2019 | 7/31/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic 250.24- AC service shall have grounded conductor bonded to a grounding electrode system described in 250.52. No GEC or grounding electrode found. 300.4- Nail plates needed in master bed and family room marked with X. 314.25- Recessed can over master shower shall have junction box cover installed to completely cover opening. 330.12- MC and NM cables shall not be installed where subject to damage. Cut corner at top of north wall. 330.30- Secure and support MC for mini split systems.
|