Information based on query as of Wednesday, May 15, 2024.
Permit Information
Permit NumberELE19-02621
StatusFinaled
Name L & K ELECTRIC
Site Address 820 W BRUMBACK ST
Project Name 
Customer Number10819
ePlanReviewNo
Description
Alteration or Repair: Electrical work for remodeling garage to accommodate a living space above.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/5/201911/6/201911/6/2019PPASS
DetailsMark Moncarr
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Ok final.
Electrical Rough-In7/25/20197/26/20197/26/2019PPASS
DetailsMark Moncarr
Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Ok cover above garage. Talked to Corbin about installing a couple of outlets on back of half wall.
Electrical Rough-In7/15/20197/16/20197/16/2019ANR
DetailsRock A. Hudson
Rough in inspection and consult with a few questions regarding job. Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg
Rough in not ready
Discussed removing subfeed from house to garage due to equipment ground must be added and small conduit between. Metal underground water pipe from house to garage must be added to grounding electrode system. Up bath does not have a basin in stool room so dedicated circuit not required. If clothes rod present in closet then AFCI protection required upstairs.
Contractor believes he will pull sub feed to panel in garage from service mounted on garage eliminating most code issues.