Final | 9/10/2019 | 9/10/2019 | 9/10/2019 | P | PASS |
James Ady
|
|
|
Electrical final please. Thank you and have a bless day!!! Phone #: ###-#### Inspection requested via web by Kyle Lott Final ok
|
Rough-In Permanent Service | 9/10/2019 | 9/10/2019 | 9/10/2019 | P | PASS |
James Ady
|
|
|
Electrical final please. Thank you and have a bless day!!! Phone #: ###-#### Inspection requested via web by Kyle Lott Rough in ok
|
Final | 9/6/2019 | 9/6/2019 | 9/6/2019 | P | FAIL |
Rock A. Hudson
|
|
|
Final inspection please. Thank you! Phone #: ###-#### Inspection requested via web by Kyle Lott 300.15- All cables shall terminate in a box. Upstairs MC up thru floor with 5' of loose wire and open stripped ends exposed. 314.25- All boxes shall have covers. Open junction box in ceiling against wall. Open switch box 330.30- MC shall be secured with in 12" of a box. Couple locations.
|
Electrical Rough-In | 7/30/2019 | 7/31/2019 | 7/31/2019 | A | PASS |
Eric Story
|
|
|
Electrical rough in please. Thank you. Have a bless day! Phone #: ###-#### Inspection requested via web by Kyle Lott Upstairs area ok to cover. No floor outlet at this time until they decide to change area to conference room in the future...
|