Final | 11/7/2019 | 11/7/2019 | 11/7/2019 | P | PASS |
Eric Story
|
|
|
This is a request for a re-inspection. Phone #: ###-#### Inspection requested via web by Dan Surerus Corrections fixed final ok
|
Final | 11/6/2019 | 11/6/2019 | 11/6/2019 | P | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Dan Surerus 210.70A2(3) There shall be a wall switch at each floor level with outside entry where the stairway between has 6 treads or more. (Stairwell)
|
Electrical Rough-In | 9/20/2019 | 9/23/2019 | 9/23/2019 | A | PASS |
James Ady
|
|
|
rough-in inspection on the upstairs. Phone #: ###-#### Inspection requested via web by Dan Surerus up stair walls only ok to cover
|
Electrical Rough-In | 9/18/2019 | 9/19/2019 | 9/19/2019 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Dan Surerus Basement only ok to cover
|
Permanent Service | 9/16/2019 | 9/17/2019 | 9/17/2019 | A | PASS |
Rock A. Hudson
|
|
|
This inspection is for reconnection of existing service. Phone #: ###-#### Inspection requested via web by Dan Surerus Discussed wiring in foam walls. Shall be 1 1/4" from framing surface for protected from physical damage. Cutting 2 1/2" deep notches in foam for channels. p/s o/h rec ok
|