Final | 5/29/2019 | 5/29/2019 | 5/29/2019 | P | PASS |
Brian Scoles
|
|
|
GARAGE CODE 3484 Phone #: ###-#### Inspection requested via web by Oleg Chervak- fireplace and hvac final ok
|
Final | 5/21/2019 | 5/24/2019 | 5/24/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- no air balance report, approved man j or duct blast has been done- line set needs tied into coil- reschedule when completed
|
Rough-in | 3/20/2019 | 3/20/2019 | 3/20/2019 | P | PASS |
Brian Scoles
|
|
|
HVAC R/I and fireplace R/I ok
|
Pressure Test | 3/20/2019 | 3/20/2019 | 3/20/2019 | P | PASS |
Brian Scoles
|
|
|
20lb gas pass- tagged meter location- 5lb flue test pass
|
Rough-in | 3/19/2019 | 3/20/2019 | 3/20/2019 | A | FAIL |
Brian Scoles
|
|
|
RE-INSPECTION, REQUEST 11AM Phone #: ###-#### Inspection requested via web by Oleg Chervak- flue wasnt under test- all corrections not made
|
Rough-in | 3/15/2019 | 3/15/2019 | 3/15/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need flue under test/gas test fail under 20psi- need to insulate supply and R/A ducts in joist above furnace- need to seal inside all boots 2nd floor supply and return- fireplace installation instructions need to easily accessed its behind glass- insulation on wye branch 2nd floor at stairs needs vapor barrier on it exposed insulation- need to secure b vent for water heater in chase and attic 2nd floor-need to seal dryer duct where enters termination box- left correction notice front entry window
|
Pressure Test | 3/15/2019 | 3/15/2019 | 3/15/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need flue under test/ gas test failed gauge below 20psi
|