Information based on query as of Friday, May 10, 2024.
Permit Information
Permit NumberMEC19-01958
StatusFinaled
Name ALLEY HEATING & COOLING
Site Address 2100 N WOODCREEK ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: FURNACE, DUCT-WORK, WATER HEATER B-VENT, 80% FURNACE B-VENT, BATHROOM VENT, KITCHEN VENT, GAS PIPING, T-STAT. FIRE PLACE.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/22/20197/23/20197/23/2019APASS
DetailsBrian Scoles
LATTER WILL BE LEFT FOR YOU. GARAGE CODE 0425 Phone #: ###-#### Inspection requested via web by Oleg Chervak
Final7/22/20197/22/20197/22/2019PFAIL
DetailsBrian Scoles
GC 0425 Phone #: ###-#### Inspection requested via web by Oleg Chervak- garage code does not work need right code to access- is there a ladder onsite to access attic at final ? will need one provided
Final7/19/20197/19/20197/19/2019PFAIL
DetailsBrian Scoles
GARAGE CODE 0425 Phone #: ###-#### Inspection requested via web by Oleg Chervak- need ladder to access attic- need to connect condenser to lineset outside
Rough-in5/16/20195/16/20195/16/2019PPASS
DetailsBrian Scoles
fireplace r/i ok
Rough-in5/16/20195/16/20195/16/2019PPASS
DetailsBrian Scoles
corrections made, latter will be provided. please call me when on your way, so we can walk through with you. thanks Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok- will look at condensate, b vent connection to furnace and line set in attic at final-
Pressure Test5/16/20195/16/20195/16/2019PPASS
DetailsBrian Scoles
corrections made, latter will be provided. please call me when on your way, so we can walk through with you. thanks Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
Rough-in5/10/20195/13/20195/13/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- gas gauge wont zero out- releive undo stress on 1/2" gas line to range fitting has lots of pressure on it
2-need ladder provided by contractor to access furnace/coil in attic
3- need 24" wide access platform installed from attic access to furnace platform unobstructive may need to reroute all duct to achieve
4- dryer duct needs sealed to termination box
5-10" supply 2nd floor loft needs moved to center of room like man j shows
6-b vent in attic will need 1" clearance to electrical wiring
7-primary condensate drain needs routed with out pressure on it with 1/4" per foot slope
8- missing transfer register 2nd floor bedrooms
9-wh b vent in chase 2nd floor needs secured
10-supply 1st floor needs moved to windows as man j shows
11- electrical switch needs to be located next to attic access for luminare
left correction n otice back windows
Pressure Test5/13/20195/13/20195/13/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out stuck on 17psi- need to relieve undo stress on 1/2" gas line to range fitting in ceiling has lots of stress on it