Final | 7/22/2019 | 7/23/2019 | 7/23/2019 | A | PASS |
Brian Scoles
|
|
|
LATTER WILL BE LEFT FOR YOU. GARAGE CODE 0425 Phone #: ###-#### Inspection requested via web by Oleg Chervak
|
Final | 7/22/2019 | 7/22/2019 | 7/22/2019 | P | FAIL |
Brian Scoles
|
|
|
GC 0425 Phone #: ###-#### Inspection requested via web by Oleg Chervak- garage code does not work need right code to access- is there a ladder onsite to access attic at final ? will need one provided
|
Final | 7/19/2019 | 7/19/2019 | 7/19/2019 | P | FAIL |
Brian Scoles
|
|
|
GARAGE CODE 0425 Phone #: ###-#### Inspection requested via web by Oleg Chervak- need ladder to access attic- need to connect condenser to lineset outside
|
Rough-in | 5/16/2019 | 5/16/2019 | 5/16/2019 | P | PASS |
Brian Scoles
|
|
|
fireplace r/i ok
|
Rough-in | 5/16/2019 | 5/16/2019 | 5/16/2019 | P | PASS |
Brian Scoles
|
|
|
corrections made, latter will be provided. please call me when on your way, so we can walk through with you. thanks Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok- will look at condensate, b vent connection to furnace and line set in attic at final-
|
Pressure Test | 5/16/2019 | 5/16/2019 | 5/16/2019 | P | PASS |
Brian Scoles
|
|
|
corrections made, latter will be provided. please call me when on your way, so we can walk through with you. thanks Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
|
Rough-in | 5/10/2019 | 5/13/2019 | 5/13/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- gas gauge wont zero out- releive undo stress on 1/2" gas line to range fitting has lots of pressure on it 2-need ladder provided by contractor to access furnace/coil in attic 3- need 24" wide access platform installed from attic access to furnace platform unobstructive may need to reroute all duct to achieve 4- dryer duct needs sealed to termination box 5-10" supply 2nd floor loft needs moved to center of room like man j shows 6-b vent in attic will need 1" clearance to electrical wiring 7-primary condensate drain needs routed with out pressure on it with 1/4" per foot slope 8- missing transfer register 2nd floor bedrooms 9-wh b vent in chase 2nd floor needs secured 10-supply 1st floor needs moved to windows as man j shows 11- electrical switch needs to be located next to attic access for luminare left correction n otice back windows
|
Pressure Test | 5/13/2019 | 5/13/2019 | 5/13/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out stuck on 17psi- need to relieve undo stress on 1/2" gas line to range fitting in ceiling has lots of stress on it
|