DOC - Permit Finaled | 12/17/2019 | 12/17/2019 | 12/17/2019 | P | PASS |
Jack Reynolds
|
|
|
final ok
|
Pressure Test | 12/17/2019 | 12/17/2019 | 12/17/2019 | P | PASS |
Jack Reynolds
|
|
|
call ###-#### for any questions Phone #: ###-#### Inspection requested via web by brett hoopes - 20lb gas pressure test - tagged meter
|
Pressure Test | 12/6/2019 | 12/6/2019 | 12/6/2019 | P | FAIL |
Jack Reynolds
|
|
|
gage on east sie of house,call if lock box is needed, gas line is visable in crawl outsideback yard access Phone #: ###-#### Inspection requested via web by brett hoopes -gas piping outside needs to be 3.5" above ground. Where gas line enters basment gas line also needs to be 3.5" above ground - gas line penetration needs 10mill tape installed and penetration sealed -gas line needs supported in basement and outside of house
|