Information based on query as of Saturday, May 4, 2024.
Permit Information
Permit NumberMEC20-02689
StatusFinaled
Name STIEGER JANICE L
Site Address 3303 S BRAMPTON WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: New gas fireplace, replacing old gas fireplace
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/5/20207/6/20207/6/2020APASS
DetailsJack Reynolds
New fireplace inspection Phone #: ###-#### Inspection requested via web by John Menzel
- fireplace R/I ok
- need to add range hood venting and dryer venting to permit. will be able to inspect both at final
Final6/30/20207/2/20207/2/2020AFAIL
DetailsJack Reynolds
New fireplace inspection Phone #: ###-#### Inspection requested via web by John Menzel
- fireplace framing need to be per instructions 49" wide with 1/2" clearances on sides
- gas piping needs to be rigid into fireplace cabinet
- venting termination needs to terminate outside and above existing chimney cap