Information based on query as of Thursday, May 9, 2024.
Permit Information
Permit NumberPLM18-03830
StatusFinaled
Name PRIME PLUMBING LLC
Site Address 2918 S GREBE PL
Project Name 
Customer Number789
ePlanReviewNo
Description
Complete Plumbing Installation: New Residential Plumbing Construction
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/17/20191/18/20191/18/2019APASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Kevin Smith
Final1/17/20191/18/20191/17/2019PCANC
DetailsEric Strole
Phone #: ###-#### >> Inspection requested via web by Kevin Smith Inspection cancelled from web by: Kevin Smith
Final1/10/20191/11/20191/11/2019PFAIL
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Kevin Smith-Still need shut off valve for water softner. Need to fix leak at water softner. Master bath lave fct not complete. No water turned in to upstairs lavs in right side bath.
Final1/8/20191/9/20191/9/2019PFAIL
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Kevin Smith-Need to turn in hot water. Need shut off valve for water softner. Pvc is not approved for water inside building. (water softner) Need to use glue and primer on water heater flue.
Plumbing Rough-in10/1/201810/1/201810/1/2018APASS
DetailsEric Strole
Plumbing Rough-in9/25/20189/25/20189/25/2018PCANC
DetailsEric Strole
Phone #: ###-#### >> Inspection requested via web by Kevin Smith Inspection cancelled from web by: Kevin Smith
Plumbing Rough-in9/24/20189/24/20189/24/2018APEND
DetailsEric Strole
-Not passing plumbing or mechanical till we figure out who is installing water heater flue. Test on flue fail & missing nailplates.
Plumbing Rough-in9/19/20189/20/20189/20/2018PPASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Kevin Smith
Plumbing Rough-in9/17/20189/19/20189/19/2018PFAIL
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Kevin Smith-DWV & water test fail. Need to fix reverse grade on dwv in overhead & crawl. Need to complete water heater flue & test.
Plumbing Rough-in9/14/20189/17/20189/17/2018PCANC
DetailsEric Strole
Phone #: ###-#### >> Inspection requested via web by Kevin Smith