Inspections for the day of: Friday, January 10, 2003.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-01185 ELE-Aging Inspection1/10/20031/10/20031/10/2003 12:00:00 AM CANC
no longer connected or inuse 1/13/2003 10:19:14 AM
ELE02-01057 ELE-Aging Inspection1/10/20031/10/20031/10/2003 12:00:00 AM PASS
ELE02-03531 Electrical Rough-In1/8/20031/10/20031/10/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 01/08/2003 at 14:01:43. Contact: ###-####.
ELE02-03278 Final1/9/20031/10/20031/10/2003 12:00:00 AMAPASS
###-####
ELE03-00050 Rough-In Permanent Service1/9/20031/10/20031/10/2003 12:00:00 AMAPART
###-####
ok for concrete 1/10/2003 10:00:43 AM
ELE98-02031 Electrical Rough-In1/9/20031/10/20031/10/2003 12:00:00 AMADONE
renie--cell ###-####-
Had conf.
cover required for furnace switch, line load reversed in bath recep. fix fan in laundry room,
disconnect power to hot tub and out building. 1/10/2003 9:07:44 AM
ELE03-00065 Final1/9/20031/10/20031/10/2003 12:00:00 AMPNR
call 1st before insp craig ###-####
will list as a sign 1/10/2003 5:01:21 PM
ELE03-00078 Temporary Service1/10/20031/10/20031/10/2003 12:00:00 AMPPASS
emmett ###-####
T/S O/H Ok 1/13/2003 9:42:01 AM
ELE03-00079 Electrical Rough-In1/10/20031/10/20031/10/2003 12:00:00 AMPPASS
kevin-- ###-#### --call 1st before insp for access
ELE03-00004 Final1/10/20031/10/20031/10/2003 12:00:00 AMPFAIL
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
314.28 and deration of conductors 1/10/2003 3:13:09 PM
ELE03-00014 Final1/10/20031/10/20031/10/2003 12:00:00 AMPFAIL
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
314.28 (a)(2) 1/10/2003 3:13:56 PM
ELE02-02745 Final1/10/20031/10/20031/10/2003 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 01/10/2003 at 09:01:23. Contact: ###-####.
ELE02-03955 Final1/10/20031/10/20031/10/2003 12:00:00 AMPFAIL
jennifer homeowner- call 1st before insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
bond water within 5 ft 1/10/2003 1:19:13 PM
ELE03-00029 Rough-In Permanent Service1/10/20031/10/20031/10/2003 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 01/10/2003 at 11:02:36. Contact: ###-####.

314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies.
Boxes and conduit bodies shall be of sufficient size to provide free space for all enclosed conductors. In no case shall the volume of the box, as calculated in 314.16(A), be less than the fill calculation as calculated in 314.16(B).

210.52 Dwelling Unit Receptacle Outlets.
(A) General Provisions. In every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, or similar room or area of dwelling units, receptacle outlets shall be installed in accordance with the general provisions specified in 210.52(A)(1) through (A)(3).

314.17 Conductors Entering Boxes, Conduit Bodies, or Fittings.
Conductors entering boxes, conduit bodies, or fittings shall be protected from abrasion and shall comply with 314.17(A) through (D).

300.4 Protection Against Physical Damage.
Where subject to physical damage, conductors shall be adequately protected.

250.148 Continuity and Attachment of Equipment Grounding Conductors to Boxes.
1/10/2003 4:17:33 PM