Inspections for the day of: Wednesday, January 10, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD17-03734 BLD-Framing/Rough-in1/9/20181/10/20181/10/2018 5:29:20 PMPPASS
Phone #: ###-#### Inspection requested via web by Tom Wells
BLD17-03969 BLD-Energy code compliance1/9/20181/10/20181/10/2018 3:15:28 PMPPASS
After 2 pm if possible please. Phone #: ###-#### Inspection requested via web by Tom Wells
BLD17-03581 BLD-Footing1/9/20181/10/20181/10/2018 3:05:38 PMPPASS
Dane Phone #: ###-####
BLD16-04474 BLD-Wall Bracing1/10/20181/10/20181/10/2018 2:14:22 PMPFAIL
Sam Phone #: ###-####. Complete install of holdowns and nail off missed areas.
BLD16-04473 BLD-Wall Bracing1/10/20181/10/20181/10/2018 2:14:00 PMPFAIL
Sam Phone #: ###-####. Complete install of holdowns and nail off missed areas.
BLD16-02757 BLD-Framing/Rough-in1/10/20181/10/20181/10/2018 2:13:23 PMPFAIL
Sam Phone #: ###-####. Unit has been insulated. Remove insulation for framing inspection.
BLD16-02743 BLD-Energy code compliance1/10/20181/10/20181/10/2018 1:46:51 PMPPASS
Sam Phone #: ###-####
BLD16-02744 BLD-Energy code compliance1/10/20181/10/20181/10/2018 1:46:35 PMPPASS
Sam Phone #: ###-####
BLD17-00553 BLD-Energy code compliance1/9/20181/10/20181/10/2018 1:28:15 PMPPASS
Thank you! Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD17-00058 BLD-Framing/Rough-in1/9/20181/10/20181/10/2018 10:59:32 AMAPART
Late am inspection please Phone #: ###-#### Inspection requested via web by Roger Graves. Add additional steel stud under joist for full bearing. 5/8 through bolts on side entry need to penetrate through osb, and stud back and connected with 1/4 inch washers and nut. ok to insulate. Also inspected in progress work on heavy timber connections on ground.
BLD16-04310 BLD-Final1/9/20181/10/20181/10/2018 9:56:24 AMAPASS
Phone #: ###-#### Inspection requested via web by David Scaggs. Ok for temp occ. Will be ok for perm occ. once zoning and public works sign perm.
BLD17-04059 BLD-Other1/9/20181/10/20181/10/2018 9:31:58 AMAPASS
call 20 min before to meet // tie down insp // Victoriano Phone #: ###-####. Needs to provide frost protection for front (south) footing.
BLD17-04532 BLD-Framing/Rough-in1/9/20181/10/20181/10/2018 9:17:27 AMAPASS
Call half hour before to meet // Tim Phone #: ###-####. Interior steel stud framed walls ok.
BLD17-04480 BLD-Foundation1/9/20181/10/20181/10/2018 8:35:49 AMAPART
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo