Inspections for the day of: Wednesday, January 11, 2006.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAlan Hauser
TitleMEC-COM/RES INSPECTOR
Phone #794-9453
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC06-00112 Rough-in1/11/20061/11/20061/11/2006 4:26:44 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Shelley Baisch
MEC06-00039 Final1/10/20061/11/20061/11/2006 4:26:30 PMPFAIL
locked and no answer to phone call
MEC06-00114 Rough-in1/11/20061/11/20061/11/2006 4:25:43 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Shelley Baisch
MEC06-00091 Rough-in1/11/20061/11/20061/11/2006 2:44:31 PMPPART
carl; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles duct ok, no equipment or diff hook up at grid yet
MEC06-00113 Rough-in1/11/20061/11/20061/11/2006 1:46:13 PMPFAIL
all metal in attic to be insulated r-5
MEC05-01939 Rough-in1/10/20061/11/20061/11/2006 1:23:11 PMPPASS
Scheduled by a contractor via Hello! on 1/10/2006 at 3:08:22 PM. Contact: ###-####.
MEC05-03270 Final1/11/20061/11/20061/11/2006 1:04:26 PMPPASS
MEC05-01180 DOC - Permit Finaled1/11/20061/11/20061/11/2006 12:53:41 PMPPASS
MEC05-01056 DOC - Permit Finaled1/11/20061/11/20061/11/2006 12:53:19 PMPPASS
MEC06-00110 Pressure Test1/11/20061/11/20061/11/2006 12:52:52 PMPPART
Phone #: ###-#### Internet Inspection Request from: don headrick pressure test ok, remove straps at wall and need one more nail (listed) plate
MEC06-00115 Final1/11/20061/11/20061/11/2006 12:26:11 PMPFAIL
all duct above grid and below roof insulation to be insulated r-5 as per 2003 IEEC
MEC06-00109 Pressure Test1/10/20061/11/20061/11/2006 10:49:00 AMAPASS
###-#### - todd
MEC06-00108 Pressure Test1/10/20061/11/20061/11/2006 10:48:46 AMAPASS
###-#### - todd
MEC05-03346 Final1/10/20061/11/20061/11/2006 10:34:07 AMAPASS
Scheduled by a contractor via Hello! on 1/10/2006 at 3:59:06 PM. Contact: ###-####.
MEC05-01180 MEC-Aging Inspection1/11/20061/11/20061/11/2006 10:22:05 AM FAIL
MEC05-01056 MEC-Aging Inspection1/11/20061/11/20061/11/2006 10:21:43 AM FAIL
MEC05-03297 Final1/10/20061/11/20061/11/2006 10:21:07 AMAPASS
Phone #: ###-#### Internet Inspection Request from: APRIL THOMAS
MEC05-03515 Final1/10/20061/11/20061/11/2006 10:07:39 AMAPASS
Scheduled by a contractor via Hello! on 1/10/2006 at 3:54:57 PM. Contact: ###-####.
MEC05-00492 MEC-Aging Inspection1/11/20061/11/20061/11/2006 9:45:38 AM CANC
MEC05-03035 Final1/10/20061/11/20061/11/2006 9:44:12 AMAPASS
Please call for garage access code.; Phone #: ###-#### Internet Inspection Request from: DeAnna Barrett
MEC06-00030 Final1/4/20061/11/20061/11/2006 9:28:53 AMANR
PLEASE CALL HOMEOWNER AT ###-#### BEFORE GOING. DO A FINAL INSP PLEASE Internet Inspection Request from: Andrea Creek won't be installed until friday