Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02974 Final1/10/20071/11/20071/11/2007 4:03:43 PMPPASS
Phone #: ###-#### called about covers, ok to final
ELE06-02615 Electrical Rough-In1/11/20071/11/20071/11/2007 3:55:29 PMPPART
buster; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover sw outside wall with brick, told to call for other wall inspections
ELE06-01645 Electrical Rough-In1/11/20071/11/20071/11/2007 3:18:06 PMPFAIL
brian - call 30 min prior to inspection please; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met owner, left corr notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(D) bath recpts shall be on wall or partition adjacent to basin, 210.52(A) recpts shall be installed on bedroom wall, BCC no violations shall be retained
ELE06-02121 Electrical Rough-In1/11/20071/11/20071/11/2007 3:08:06 PMPPASS
lauren; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr made, ric ok
ELE07-00129 Electrical Rough-In1/11/20071/11/20071/11/2007 2:26:46 PMPPASS
roger ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric ok, called , need to see new east walls
ELE06-02602 Electrical Rough-In1/11/20071/11/20071/11/2007 1:20:08 PMPPASS
ron - please call 1/2 hr prior to inspection ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corr made, ric ok
ELE07-00131 Final1/11/20071/11/20071/11/2007 10:29:34 AMAPASS
ok to final
ELE07-00131 Electrical Rough-In1/11/20071/11/20071/11/2007 10:24:59 AMAPASS
called to add cover to open box
ELE07-00050 Electrical Rough-In1/10/20071/11/20071/11/2007 10:24:00 AMACANC
READY FOR INSPECTION OF TRACK LIGHTING Phone #: ###-#### x0000 wrong address, wrong permit
ELE07-00008 Electrical Rough-In1/10/20071/11/20071/11/2007 9:59:36 AMAFAIL
jake - note cell# for lock box code ###-#### or ###-####; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called contr, left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from face of framing members, 210.52(A)(1) no wall space shall be over 6' from recpt, 334.30 nm cable shall be strapped within 12" of box, 240.24(B) each occupant shall have access to all overcurrent devices for that occupancy
ELE07-00063 Rough-In Permanent Service1/10/20071/11/20071/11/2007 8:42:48 AMAPASS
daryl - unattached garage also ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric ok both house and garage, need to see trench between two, p/s o/h n ok
ELE06-02364 Final1/10/20071/11/20071/11/2007 8:39:59 AMAPASS
Scheduled by a contractor via Hello! on 1/10/2007 at 3:09:52 PM. Contact: ###-####. approval on listing ok, ok to final, signed occ card