Inspections for the day of: Monday, January 11, 2016.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-04103 Conference1/7/20161/11/20161/11/2016 1:49:45 PMPDONE
This consultation will be for upgrading the existing gear. Please give me a call beforehand so I can meet you there. Thank you Phone #: ###-#### Inspection requested via web by Thomas Jenkins discussed replacing old guts in panel board and installing new panel inside. Contractor will fabricate deed front to protect conductors and personnel
ELE15-03670 Final1/11/20161/11/20161/11/2016 1:43:17 PMPFAIL
Lock box is in mailbox and the code is 7448 Phone #: ###-#### Inspection requested via web by Randy Fletcher 210.52 (g)(1) branch circuit shall not supply any outlets outside of building 210.8(a)(5) in unfinished basements all 120v receptacles shall have GFCI protection Funds required to permit for final
ELE13-01733 ELE-Aging Inspection1/11/20161/11/20161/11/2016 12:56:54 PM DONE
called and left a message
ELE15-04101 Temporary Service1/11/20161/11/20161/11/2016 12:50:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE16-00075 Electrical Rough-In1/11/20161/11/20161/11/2016 12:05:45 PMPPASS
Please inspect grounding electrode on garage wall. Any questions please call if you have any questions please call ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman grounding electrode on garage wall ok pour
ELE15-04128 Rough-In Permanent Service1/9/20161/11/20161/11/2016 9:41:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Idsinga rough-in ok cover p/s o/h n ok
ELE15-04127 Rough-In Permanent Service1/9/20161/11/20161/11/2016 9:37:55 AMAFAIL
Phone #: ###-#### Inspection requested via web by Greg Idsinga 334.30 type nm cable shall be within 4 1/2' between supports
ELE15-04129 Electrical Rough-In1/9/20161/11/20161/11/2016 9:36:46 AMAFAIL
Phone #: ###-#### Inspection requested via web by Greg Idsinga 334.15 type nm cable shall be protected from physical damage
ELE16-00049 Temporary Service1/11/20161/11/20161/11/2016 9:07:01 AMPPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman t/s u/g n ok