Inspections for the day of: Wednesday, January 11, 2017.
Number of inspections: 4
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02998 ELE-Aging Inspection1/11/20171/11/20171/19/2017 1:22:26 PM PASS
Will check after snow melt for access. Drove by.
ELE12-01429 ELE-Aging Inspection1/11/20171/11/20171/19/2017 1:10:43 PM DONE
Drove by will check when snow has melted off
ELE17-00037 Conference1/9/20171/11/20171/12/2017 11:07:16 AMADONE
Consult about new code requirements in old building. Contact Tom Betty. Phone #: ###-#### Inspection requested via web by Cathy Duchek
Discussed electrical requirements of remodel. Walls will not have drywall removed will be repainted. Patches will be created to add microwave circuits. Surface mounted conduits shall be listed assembly, receptacles shall be tamper resistant type, range receptacles shall be 4 wire, bedroom areas not required to be AFCI protected due to no new wiring being installed, check with Building inspector on ADA requirements for units that may be marketed as ADA. Panels may need lowered to comply. Temp wiring feeding sign not compliant, GFCI protection, installed by unlicensed person, shall repair with in 5 working days. Will schedule reinspect for temp wiring for Wed. 1-18-17.
ELE16-04041 Electrical Rough-In1/11/20171/11/20171/11/2017 1:18:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Checked listing on a LED mud in luminaire with drivers above grid. Discussed GFCI devices located in readily accessible locations. Some noticed above 6'7" on walls and in ceiling.
Bar recessed hardlids rough in ok cover