ELE13-01780
| ELE-Aging Inspection | 1/12/2016 | 1/12/2016 | 1/12/2016 3:25:34 PM | | DONE |
|
|
Drove by and inspected
|
ELE13-01780
| Final | 1/12/2016 | 1/12/2016 | 1/12/2016 3:21:49 PM | P | PASS |
|
|
Disconnecting means and listing confirmed. Final ok
|
ELE13-01785
| ELE-Aging Inspection | 1/12/2016 | 1/12/2016 | 1/12/2016 3:07:32 PM | | DONE |
|
|
Drove by and inspected
|
ELE13-01785
| Final | 1/12/2016 | 1/12/2016 | 1/12/2016 2:56:13 PM | P | PASS |
|
|
Disconnecting means and listing confirmed. Final ok
|
ELE13-01775
| ELE-Aging Inspection | 1/12/2016 | 1/12/2016 | 1/12/2016 2:53:24 PM | | DONE |
|
|
Drove by and inspected
|
ELE13-01775
| Final | 1/12/2016 | 1/12/2016 | 1/12/2016 2:44:38 PM | P | PASS |
|
|
Disconnecting means and listing confirmed. Final ok
|
ELE16-00042
| Rough-In Permanent Service | 1/12/2016 | 1/12/2016 | 1/12/2016 2:40:11 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey 300.4- Furnace where NM cable passes through metal hole it shall be protcted from physical damage by bushing/connector. 300.4(G)- Raceway or connectors containing #4 or larger conductors shall have bushing installed to protect wiring. 314.17(C)- NM cable sheathing shall enter box minimum of 1/4". Ding room. 334.30- NM cable shall not be scured on edge. 250.134- Metal box in net panel shall be connnected to equipment grounding conductor.
|
ELE16-00043
| Rough-In Permanent Service | 1/12/2016 | 1/12/2016 | 1/12/2016 2:30:29 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey 210.52(A)(2)1- Walls 2' or wider shall have a receptacle outlet install to serve wall space. 250.134- Metal box in net panel shall be connected to equipment grounding conductor. 300.4- In garage gronding electrode conductor wher ran through bored holes that do not maintain 1 1/4" from framing surface shall be protected from physical damage by nail plates. 300.4(G)- Raceways or connectors containing #4 or larger conductors shall have a bushing installed to protect wiring. 352.48- All joints between conduit bodies shall be done by an approved method. Garage LB to junction box. Glue BA to LB.
|
ELE16-00092
| Permanent Service | 1/12/2016 | 1/12/2016 | 1/12/2016 1:14:59 PM | P | PASS |
|
|
early afternoon if possible Phone #: ###-#### Inspection requested via web by John VanZandt p/s o/h rec ok
|
ELE15-03791
| Final | 1/12/2016 | 1/12/2016 | 1/12/2016 12:43:38 PM | P | PASS |
|
|
David Phone #: ###-#### Final ok
|
ELE16-00084
| Temporary Service | 1/11/2016 | 1/12/2016 | 1/12/2016 11:39:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
|
ELE15-04107
| Final | 1/11/2016 | 1/12/2016 | 1/12/2016 11:07:20 AM | A | PASS |
|
|
Ron Phone #: ###-#### Final ok
|
ELE15-04108
| Electrical Rough-In | 1/12/2016 | 1/12/2016 | 1/12/2016 10:20:39 AM | A | PASS |
|
|
Under Slab Phone #: ###-#### Inspection requested via web by kendall bender Check paint mixing station and small paint booth listings and wiring methods when available. Underslab for floor outlets and data rough in ok cover
|
ELE16-00064
| Temporary Service | 1/11/2016 | 1/12/2016 | 1/12/2016 9:51:09 AM | A | PASS |
|
|
ReInsepect for Temp Power Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence t/s u/g n ok
|
ELE16-00086
| Conference | 1/11/2016 | 1/12/2016 | 1/12/2016 9:34:02 AM | A | DONE |
|
|
Please call Clay to meet you there ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Discussed burn job with knob and tube wiring with insulation installed. BCC 4-05-32- Code violation not to be retained. 394.12(5)- Concealed knob and tube wiring shall not installed where in contact with thermal insualtion
|
ELE15-03951
| Final | 1/11/2016 | 1/12/2016 | 1/12/2016 8:46:23 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe Final ok
|