Inspections for the day of: Tuesday, January 12, 2016.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01780 ELE-Aging Inspection1/12/20161/12/20161/12/2016 3:25:34 PM DONE
Drove by and inspected
ELE13-01780 Final1/12/20161/12/20161/12/2016 3:21:49 PMPPASS
Disconnecting means and listing confirmed. Final ok
ELE13-01785 ELE-Aging Inspection1/12/20161/12/20161/12/2016 3:07:32 PM DONE
Drove by and inspected
ELE13-01785 Final1/12/20161/12/20161/12/2016 2:56:13 PMPPASS
Disconnecting means and listing confirmed. Final ok
ELE13-01775 ELE-Aging Inspection1/12/20161/12/20161/12/2016 2:53:24 PM DONE
Drove by and inspected
ELE13-01775 Final1/12/20161/12/20161/12/2016 2:44:38 PMPPASS
Disconnecting means and listing confirmed. Final ok
ELE16-00042 Rough-In Permanent Service1/12/20161/12/20161/12/2016 2:40:11 PMPFAIL
Phone #: ###-#### Inspection requested via web by Neal Rumsey
300.4- Furnace where NM cable passes through metal hole it shall be protcted from physical damage by bushing/connector.
300.4(G)- Raceway or connectors containing #4 or larger conductors shall have bushing installed to protect wiring.
314.17(C)- NM cable sheathing shall enter box minimum of 1/4". Ding room.
334.30- NM cable shall not be scured on edge.
250.134- Metal box in net panel shall be connnected to equipment grounding conductor.
ELE16-00043 Rough-In Permanent Service1/12/20161/12/20161/12/2016 2:30:29 PMPFAIL
Phone #: ###-#### Inspection requested via web by Neal Rumsey
210.52(A)(2)1- Walls 2' or wider shall have a receptacle outlet install to serve wall space.
250.134- Metal box in net panel shall be connected to equipment grounding conductor.
300.4- In garage gronding electrode conductor wher ran through bored holes that do not maintain 1 1/4" from framing surface shall be protected from physical damage by nail plates.
300.4(G)- Raceways or connectors containing #4 or larger conductors shall have a bushing installed to protect wiring.
352.48- All joints between conduit bodies shall be done by an approved method. Garage LB to junction box. Glue BA to LB.
ELE16-00092 Permanent Service1/12/20161/12/20161/12/2016 1:14:59 PMPPASS
early afternoon if possible Phone #: ###-#### Inspection requested via web by John VanZandt p/s o/h rec ok
ELE15-03791 Final1/12/20161/12/20161/12/2016 12:43:38 PMPPASS
David Phone #: ###-#### Final ok
ELE16-00084 Temporary Service1/11/20161/12/20161/12/2016 11:39:35 AMAPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
ELE15-04107 Final1/11/20161/12/20161/12/2016 11:07:20 AMAPASS
Ron Phone #: ###-#### Final ok
ELE15-04108 Electrical Rough-In1/12/20161/12/20161/12/2016 10:20:39 AMAPASS
Under Slab Phone #: ###-#### Inspection requested via web by kendall bender
Check paint mixing station and small paint booth listings and wiring methods when available.
Underslab for floor outlets and data rough in ok cover
ELE16-00064 Temporary Service1/11/20161/12/20161/12/2016 9:51:09 AMAPASS
ReInsepect for Temp Power Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence
t/s u/g n ok
ELE16-00086 Conference1/11/20161/12/20161/12/2016 9:34:02 AMADONE
Please call Clay to meet you there ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan
Discussed burn job with knob and tube wiring with insulation installed.
BCC 4-05-32- Code violation not to be retained.
394.12(5)- Concealed knob and tube wiring shall not installed where in contact with thermal insualtion
ELE15-03951 Final1/11/20161/12/20161/12/2016 8:46:23 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe
Final ok