ELE17-03141
| Final | 1/10/2018 | 1/12/2018 | 1/12/2018 2:33:41 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by William Andrews Battery terminals shall be protected as per 110.27. DC array wires shall be protected from physical damage and raceway labeled as per 690.31G3. Disc on house shall be bonded as per 250.148 Panel in basement shall be labeled as per 408.4. Replace 50A backfed breaked with 30A
|
ELE17-04329
| Final | 1/12/2018 | 1/12/2018 | 1/12/2018 12:55:46 PM | P | NR |
|
|
Pls contact Spencer (Foreman) @ ###-#### or Barry (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Christian Kilpatrick not ready
|
ELE17-02463
| Final | 1/12/2018 | 1/12/2018 | 1/12/2018 12:54:40 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Tom Jenkins partial final ok
|
ELE17-02463
| Rough-In Permanent Service | 1/12/2018 | 1/12/2018 | 1/12/2018 12:52:35 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tom Jenkins rough in ok
|
ELE18-00122
| Final | 1/11/2018 | 1/12/2018 | 1/12/2018 12:13:09 PM | P | PASS |
|
|
Call 1/2 hr prior to inspection. Call John at ###-#### Phone #: ###-#### Inspection requested via web by MIKE HAGERTY final ok
|
ELE18-00122
| Electrical Rough-In | 1/11/2018 | 1/12/2018 | 1/12/2018 12:12:35 PM | P | PASS |
|
|
Please call 1/2 prior to inspection. call john at ###-#### Phone #: ###-#### Inspection requested via web by MIKE HAGERTY rough in ok
|
ELE18-00139
| Electrical Rough-In | 1/11/2018 | 1/12/2018 | 1/12/2018 11:37:19 AM | A | PASS |
|
|
For access please call Jaman 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott main/ master bath only rough in ok
|
ELE17-04329
| Electrical Rough-In | 1/12/2018 | 1/12/2018 | 1/12/2018 11:36:37 AM | A | PASS |
|
|
Pls contact Spencer (Foreman) @ ###-#### or Barry (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Christian Kilpatrick listing only ok
|
ELE16-02746
| Electrical Rough-In | 1/11/2018 | 1/12/2018 | 1/12/2018 11:14:53 AM | A | PASS |
|
|
Rough cover soffit 409-419 Phone #: ###-#### Inspection requested via web by Kenneth Chapman Drop ceiling only ok to cover
|
ELE18-00140
| Rough-In Permanent Service | 1/11/2018 | 1/12/2018 | 1/12/2018 10:48:34 AM | A | PASS |
|
|
permanent and final inspection for cable t v power supply cabinet. alpha cabinet. located at s w corner of 805 Bergeson . in common utility area.contact ####-####, Andy Phone #: ###-#### Inspection requested via web by andrew dopieralski p/s u/g n ok
|
ELE18-00140
| Final | 1/12/2018 | 1/12/2018 | 1/12/2018 10:48:24 AM | P | PASS |
|
|
permanent and final inspection for cable t v power supply cabinet. alpha cabinet. located at s w corner of 805 Bergeson . in common utility area.contact ####-####, Andy Phone #: ###-#### Inspection requested via web by andrew dopieralski final ok
|
ELE17-03685
| Final | 1/11/2018 | 1/12/2018 | 1/12/2018 10:31:26 AM | A | PASS |
|
|
Eric Phone #: ###-#### Contractor set pedistal only. not going to wire mail facility. As per Daryl Degrang Final ok
|
ELE17-04357
| Rough-In Permanent Service | 1/12/2018 | 1/12/2018 | 1/12/2018 9:45:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok
|
ELE18-00146
| Rough-In Permanent Service | 1/11/2018 | 1/12/2018 | 1/12/2018 9:30:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok p/s u/g n ok
|
ELE18-00093
| Final | 1/12/2018 | 1/12/2018 | 1/12/2018 9:07:32 AM | A | PASS |
|
|
Final on solar disc. Final ok
|
ELE18-00040
| Electrical Rough-In | 1/11/2018 | 1/12/2018 | 1/12/2018 9:07:15 AM | A | PASS |
|
|
We will call in the morning to schedule a time to meet you onsite. Phone #: ###-#### Inspection requested via web by Jesse Simpson rough in ok
|
ELE18-00040
| Final | 1/12/2018 | 1/12/2018 | 1/12/2018 9:07:06 AM | P | PASS |
|
|
We will call in the morning to schedule a time to meet you onsite. Phone #: ###-#### Inspection requested via web by Jesse Simpson Solar final ok
|