Inspections for the day of: Friday, January 13, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-02372 ELE-Aging Inspection1/13/20061/13/20061/18/2006 9:50:17 AM DONE
see final
ELE04-01984 ELE-Aging Inspection1/13/20061/13/20061/17/2006 4:45:31 PM DONE
see final
ELE05-01433 Final1/13/20061/13/20061/13/2006 4:07:30 PMPPASS
gilbert -call 1st before insp -re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie corr made, ok to final
ELE05-02371 ELE-Aging Inspection1/13/20061/13/20061/13/2006 4:06:47 PM DONE
see final
ELE05-03777 Final1/13/20061/13/20061/13/2006 2:50:15 PMPPASS
final on new garage Internet Inspection Request from: Andy Rose called contr, left survey, 314.25 each box shall have a cover, 430.102(B) disconnect shall be provided for air compressor
ELE05-04293 Rough-In Permanent Service1/13/20061/13/20061/13/2006 2:33:05 PMPFAIL
Scheduled by a contractor via Hello! on 1/13/2006 at 10:24:15 AM. Contact: ###-####. called contr, left corr notice,312.5 conductors entering enclosures shall have abrasion protection, 334.80 more than 2 nm cables bundled and passing thru wood framing using draft stopping shall adjust ampacity of each conductor (over panel), 300.4(A)&(D) edge of hole and nm cable shall be 11/4" from edge of framing members,BCC all make-up shall be done( #12 in wall between studs)
ELE06-00116 Electrical Rough-In1/13/20061/13/20061/13/2006 1:03:24 PMPPASS
underground insp - mike ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie u/g for conduit south side bldg ok to cover.
ELE06-00130 Rough-In Permanent Service1/12/20061/13/20061/13/2006 10:31:38 AMAPASS
###-#### allen called contr, left survey, 312.5 conductors entering enclosures shall have abrasion protection, 430.107 pump motor disconnect in tub shall be readily accessible
ELE05-04651 Electrical Rough-In1/12/20061/13/20061/13/2006 10:20:17 AMAPASS
jeremy; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa walls ok to cover, hard lid ceiling ok to cover
ELE06-00097 Rough-In Permanent Service1/12/20061/13/20061/13/2006 9:54:23 AMAPASS
daryl; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ric ok, p/s u/g n ok
ELE05-03168 Final1/12/20061/13/20061/13/2006 9:32:41 AMAPASS
code= 2241; Phone #: ###-#### Internet Inspection Request from: William Zerfas called contr to finish tub access. ok to final
ELE06-00116 Electrical Rough-In1/12/20061/13/20061/13/2006 9:27:12 AMAPASS
grounding inspection//mike; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa gec only ok to backfill
ELE06-00139 Electrical Rough-In1/12/20061/13/20061/13/2006 9:25:43 AMAPASS
dave -for partial ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie halo room only ok to cover
ELE05-02371 Final1/13/20061/13/20061/13/2006 12:00:00 AMPPASS
looked at sign, ok to final