ELE10-02469
| ELE-Aging Inspection | 1/13/2011 | 1/13/2011 | 1/13/2011 3:33:45 PM | | DONE |
|
|
see final
|
ELE10-02469
| Final | 1/13/2011 | 1/13/2011 | 1/13/2011 3:33:31 PM | P | PASS |
|
|
ok
|
ELE10-02470
| ELE-Aging Inspection | 1/13/2011 | 1/13/2011 | 1/13/2011 3:31:40 PM | | DONE |
|
|
suc
|
ESC10-00497
| General Inspection | 1/13/2011 | 1/13/2011 | 1/13/2011 3:21:57 PM | P | PASS |
|
|
jnstalling sprinklers, looked ok
|
ESC10-00777
| General Inspection | 1/13/2011 | 1/13/2011 | 1/13/2011 3:04:23 PM | A | PASS |
|
|
doing drive, looked ok
|
ELE10-02121
| Final | 1/13/2011 | 1/13/2011 | 1/13/2011 2:45:22 PM | P | PART |
|
|
call first Phone #: ###-#### >> Inspection requested via web by PAT MILLER receptacles ok, will do lighting later
|
ELE11-00078
| Electrical Rough-In | 1/13/2011 | 1/13/2011 | 1/13/2011 1:51:52 PM | P | PASS |
|
|
rocky Phone #: ###-#### ri ok
|
ELE10-01904
| Final | 1/12/2011 | 1/13/2011 | 1/13/2011 12:52:08 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Josh Craig ok final
|
ELE10-02584
| Final | 1/12/2011 | 1/13/2011 | 1/13/2011 10:24:43 AM | A | PASS |
|
|
Garage code 1357 Phone #: ###-#### >> Inspection requested via web by Therrin Robertson ok final
|
ELE10-02758
| Electrical Rough-In | 1/12/2011 | 1/13/2011 | 1/13/2011 9:37:21 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left message, left correction notice, NEC 334.30 shall staple nm cable within 12" of box, 210.52(B) small appliance branch circuits shall be on 20A circuits, 210.8(A)(7) shall provide gfci protection within 6' of sinks
|
GCE11-00009
| GCE-Temporary Service | 1/12/2011 | 1/13/2011 | 1/13/2011 8:56:04 AM | A | FAIL |
|
|
Scope: Temp ServiceContact: Jeremy @ ###-#### called, left correction notice, NEC 408.4 shall provide circuit schedule, 312.5 shall provide abrasion protection, 110.14(A) shall tighten terminations, 230.71(B) shall provide suitable handle tie at trailer main, 400.5 shall provide minimum #4 flexible cord for 60A main and trailer service, 400.10 shall provide strain relief for cords at fittings, 400.14 shall protect cable from damage, BCC shall provide job id sticker
|