Inspections for the day of: Monday, January 13, 2014.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02430 Final1/13/20141/13/20141/13/2014 3:32:14 PMPPASS
Final for the new Western Aircraft warehouse. Contact is Nathan Cornell. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery final ok
ELE14-00077 Electrical Rough-In1/13/20141/13/20141/13/2014 1:25:09 PMPPASS
Please call Jeff ahead of time so I can let you in. Thanks Phone #: ###-#### >> Inspection requested via web by Brandon Blackham rough-in ok cover kitchen remodel, exsisting edison branch circuits
ELE13-03033 Final1/13/20141/13/20141/13/2014 1:03:07 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov correction done, final ok
ELE12-02104 Electrical Rough-In1/13/20141/13/20141/13/2014 12:46:54 PMPPASS
Partial R/I for garage/please call ahead for access(15min) - Trevor Phone #: ###-#### Rough-in ok Partial cover front garage door wall and ceiling 12 ft back to hang garage door hardware.
ELE13-03535 Electrical Rough-In1/10/20141/13/20141/13/2014 11:07:33 AMAPASS
call 1/2 hr before to meet // Todd Phone #: ###-#### rough-in ok cover kitchen and bathroom areas, Ask homeowner to remove bundled NM cables (homeruns) from 2in PVC to panel in basement
GCE13-00181 GCE-Rough-In1/10/20141/13/20141/13/2014 9:59:14 AMAPASS
Mark ###-#### rough-in ok cover south and east exterior walls only
ELE11-00412 Final1/10/20141/13/20141/13/2014 9:43:57 AMAPASS
customer will not be home, okay to go in backyard Phone #: ###-#### >> Inspection requested via web by Louis Keller correction done, final ok
ELE14-00069 Final1/10/20141/13/20141/13/2014 9:06:20 AMAFAIL
ROBERT Phone #: ###-#### NEC 310.15(B) NM cable not listed for wet locations.
ELE13-02849 Final1/10/20141/13/20141/13/2014 8:49:14 AMAPART
Contact is Alan Krishnek - this is a PARTIAL final for one area of the work Phone #: ###-#### >> Inspection requested via web by Scott Campbell partial final for office area only
ELE13-02849 Electrical Rough-In1/10/20141/13/20141/13/2014 8:46:08 AMAPASS
Contact is Alan Krishnek Phone #: ###-#### >> Inspection requested via web by Scott Campbell rough-in ok cover ceilings in bathrooms
ELE14-00071 Temporary Service1/10/20141/13/20141/13/2014 8:14:36 AMAPASS
Cal Phone #: ###-#### >> Inspection requested via web by cal crosby t/s u/g n ok
ELE09-01597 ELE-Aging Inspection1/13/20141/13/20141/13/2014 6:39:19 AM DONE
under review