Inspections for the day of: Tuesday, January 13, 2015.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC15-00082 Rough-in1/13/20151/13/20151/13/2015 4:36:37 PMPPASS
Oleg Phone #: ###-####
MEC15-00150 Final1/12/20151/13/20151/13/2015 4:03:37 PMPPASS
Installer Scott ###-#### Phone #: ###-#### Inspection requested via web by Dustin Rich
MEC14-05070 Rough-in1/13/20151/13/20151/13/2015 3:38:46 PMPPART
Upstairs - Hard Lid inspection
Contact Curt with any questions. 208.412.6685 Phone #: ###-#### Inspection requested via web by Bailey Esposito - elevator equipment ceiling okay to cover
MEC14-05747 Final1/13/20151/13/20151/13/2015 3:10:58 PMPFAIL
Outside unit only changed out air conditioning to heat pump Inspection requested via web by MARGIE ROWE - need water tight electrical flex between disconnect and heat pump
MEC14-05632 Rough-in1/13/20151/13/20151/13/2015 2:35:59 PMPFAIL
Bj 5730755 Inspection requested via web by william kerwin - need insulation shield on b-vent for water heater, missing a 6" supply in master bath w/c
MEC14-05632 Pressure Test1/13/20151/13/20151/13/2015 2:31:57 PMPPASS
Bj 5730755 Inspection requested via web by william kerwin - 20lb gas, 5lb flue pass
MEC14-03522 Final1/13/20151/13/20151/13/2015 2:03:09 PMPFAIL
Phone #: ###-#### Inspection requested via web by Troy Worley - air balance report shows zero cfm on second test for bedroom #2
MEC14-03829 Final1/13/20151/13/20151/13/2015 1:54:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Troy Worley
MEC15-00155 Rough-in1/13/20151/13/20151/13/2015 1:51:23 PMPPASS
Fireplace rough in pass
MEC15-00084 Rough-in1/13/20151/13/20151/13/2015 1:23:35 PMPPASS
Oleg Phone #: ###-#### - 5lb flue, rough in pass
MEC15-00148 Final1/12/20151/13/20151/13/2015 10:26:37 AMPPASS
installer Sam ###-#### Phone #: ###-#### Inspection requested via web by Dustin Rich
MEC15-00084 Rough-in1/12/20151/13/20151/13/2015 10:08:37 AMAFAIL
Oleg-late AM if possible Phone #: ###-#### - 5lb flue fail on smaller furnace
MEC15-00124 Final1/13/20151/13/20151/13/2015 9:46:52 AMAPASS
MEC14-05305 Final1/12/20151/13/20151/13/2015 9:17:06 AMAFAIL
Sarah or Randy Phone #: ###-#### - Need to install vent duct to out doors on range hood, or install a recirculation kit for range hood.
MEC15-00082 Rough-in1/12/20151/13/20151/13/2015 8:57:15 AMAFAIL
oleg Phone #: ###-#### - need 6" fresh air to return air plenum