Inspections for the day of: Thursday, January 14, 2010.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-01858 ELE-Aging Inspection1/14/20101/14/20101/14/2010 3:36:45 PM DONE
no activity, see doc expire
ELE08-01858 DOC - Permit Expired1/14/20101/14/20101/14/2010 3:36:30 PMPPASS
no activity, ok to doc expire
ELE08-01728 ELE-Aging Inspection1/14/20101/14/20101/14/2010 3:34:39 PM DONE
no activity, see doc expire
ELE08-01728 DOC - Permit Expired1/14/20101/14/20101/14/2010 3:34:24 PMPPASS
no activity, ok to doc expire
ESC09-00573 General Inspection1/14/20101/14/20101/14/2010 3:32:31 PMPPASS
looked ok
ESC09-00355 General Inspection1/14/20101/14/20101/14/2010 3:31:45 PMPPASS
looked ok
ELE10-00050 ELE-Aging Inspection1/14/20101/14/20101/14/2010 2:48:27 PMPDONE
status check for correction notice
ELE09-01826 Electrical Rough-In1/13/20101/14/20101/14/2010 2:46:12 PMPFAIL
Contact is John Dillon Phone #: ###-#### Internet Inspection Request from: Scott Campbell called contractor, left correction notice, NEC 225.36 disconnecting means shall be suitable for service equipment at each building, 348.30,330.30 fmc and mc shall be securely supported within 12" of box, 250.86 shall ground metal boxes,300.4(A)&(D) edge of bored holes and mc cables shall be 1 1/4" from edge of framing member,250.32 shall provide disconnecting means inside or outside of building served per 225.31, 250.32(B) grounded conductor shall not connect to equipment grounding conductor, 110.12(A) shall close unused openings
ESC09-00181 General Inspection1/14/20101/14/20101/14/2010 2:32:02 PMPPASS
looked ok
ELE09-02185 ELE-Aging Inspection1/14/20101/14/20101/14/2010 12:17:07 PM DONE
see final
ELE09-02185 Final1/14/20101/14/20101/14/2010 12:16:34 PMPPASS
ok to final
ELE09-01000 DOC - Permit Expired1/14/20101/14/20101/14/2010 12:01:37 PMPPASS
no activity, ok to doc expire
ELE10-00081 Electrical Rough-In1/14/20101/14/20101/14/2010 10:55:11 AMAPASS
Contact: Lyle Dean Phone #: ###-#### Internet Inspection Request from: Deb Gooden rack from electrical room, tray and boxes above ceiling ok, will see equipment drops and hook-ups later, no esc this project
ELE09-00815 Final1/13/20101/14/20101/14/2010 9:42:11 AMAPASS
call owner for access Frank Phone #: ###-#### ok to final, no esc this project
ELE09-02386 Electrical Rough-In1/13/20101/14/20101/14/2010 8:51:19 AMAPASS
Overhead service Phone #: ###-#### Internet Inspection Request from: Kurt Carlson ri for change service from u/g to o/h ok
ELE09-02386 Permanent Service1/14/20101/14/20101/14/2010 8:17:25 AMAPASS
Overhead service Phone #: ###-#### Internet Inspection Request from: Kurt Carlson changed service from u/g to o/h- p/s o/h n ok
ELE09-00852 Final1/13/20101/14/20101/14/2010 8:02:50 AMAPASS
###-#### per request ok to final