ELE08-01858
| ELE-Aging Inspection | 1/14/2010 | 1/14/2010 | 1/14/2010 3:36:45 PM | | DONE |
|
|
no activity, see doc expire
|
ELE08-01858
| DOC - Permit Expired | 1/14/2010 | 1/14/2010 | 1/14/2010 3:36:30 PM | P | PASS |
|
|
no activity, ok to doc expire
|
ELE08-01728
| ELE-Aging Inspection | 1/14/2010 | 1/14/2010 | 1/14/2010 3:34:39 PM | | DONE |
|
|
no activity, see doc expire
|
ELE08-01728
| DOC - Permit Expired | 1/14/2010 | 1/14/2010 | 1/14/2010 3:34:24 PM | P | PASS |
|
|
no activity, ok to doc expire
|
ESC09-00573
| General Inspection | 1/14/2010 | 1/14/2010 | 1/14/2010 3:32:31 PM | P | PASS |
|
|
looked ok
|
ESC09-00355
| General Inspection | 1/14/2010 | 1/14/2010 | 1/14/2010 3:31:45 PM | P | PASS |
|
|
looked ok
|
ELE10-00050
| ELE-Aging Inspection | 1/14/2010 | 1/14/2010 | 1/14/2010 2:48:27 PM | P | DONE |
|
|
status check for correction notice
|
ELE09-01826
| Electrical Rough-In | 1/13/2010 | 1/14/2010 | 1/14/2010 2:46:12 PM | P | FAIL |
|
|
Contact is John Dillon Phone #: ###-#### Internet Inspection Request from: Scott Campbell called contractor, left correction notice, NEC 225.36 disconnecting means shall be suitable for service equipment at each building, 348.30,330.30 fmc and mc shall be securely supported within 12" of box, 250.86 shall ground metal boxes,300.4(A)&(D) edge of bored holes and mc cables shall be 1 1/4" from edge of framing member,250.32 shall provide disconnecting means inside or outside of building served per 225.31, 250.32(B) grounded conductor shall not connect to equipment grounding conductor, 110.12(A) shall close unused openings
|
ESC09-00181
| General Inspection | 1/14/2010 | 1/14/2010 | 1/14/2010 2:32:02 PM | P | PASS |
|
|
looked ok
|
ELE09-02185
| ELE-Aging Inspection | 1/14/2010 | 1/14/2010 | 1/14/2010 12:17:07 PM | | DONE |
|
|
see final
|
ELE09-02185
| Final | 1/14/2010 | 1/14/2010 | 1/14/2010 12:16:34 PM | P | PASS |
|
|
ok to final
|
ELE09-01000
| DOC - Permit Expired | 1/14/2010 | 1/14/2010 | 1/14/2010 12:01:37 PM | P | PASS |
|
|
no activity, ok to doc expire
|
ELE10-00081
| Electrical Rough-In | 1/14/2010 | 1/14/2010 | 1/14/2010 10:55:11 AM | A | PASS |
|
|
Contact: Lyle Dean Phone #: ###-#### Internet Inspection Request from: Deb Gooden rack from electrical room, tray and boxes above ceiling ok, will see equipment drops and hook-ups later, no esc this project
|
ELE09-00815
| Final | 1/13/2010 | 1/14/2010 | 1/14/2010 9:42:11 AM | A | PASS |
|
|
call owner for access Frank Phone #: ###-#### ok to final, no esc this project
|
ELE09-02386
| Electrical Rough-In | 1/13/2010 | 1/14/2010 | 1/14/2010 8:51:19 AM | A | PASS |
|
|
Overhead service Phone #: ###-#### Internet Inspection Request from: Kurt Carlson ri for change service from u/g to o/h ok
|
ELE09-02386
| Permanent Service | 1/14/2010 | 1/14/2010 | 1/14/2010 8:17:25 AM | A | PASS |
|
|
Overhead service Phone #: ###-#### Internet Inspection Request from: Kurt Carlson changed service from u/g to o/h- p/s o/h n ok
|
ELE09-00852
| Final | 1/13/2010 | 1/14/2010 | 1/14/2010 8:02:50 AM | A | PASS |
|
|
###-#### per request ok to final
|