Inspections for the day of: Thursday, January 14, 2010.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD09-00739 BLD-Framing/Rough-in1/14/20101/14/20101/14/2010 4:07:00 PMPNR
Firewall construction Phone #: ###-#### Internet Inspection Request from: James Larkin. Will reschedule.
BLD09-00740 BLD-Framing/Rough-in1/14/20101/14/20101/14/2010 4:06:40 PMPNR
Firewall construction Phone #: ###-#### Internet Inspection Request from: James Larkin Will reschedule.
MIS10-00008 BLD-Conference1/14/20101/14/20101/14/2010 3:34:14 PMPFAIL
report reroofing without permit
MIS10-00008 DOC - Permit Finaled1/14/20101/14/20101/14/2010 3:34:05 PMPPASS
BLD09-00846 BLD-Final1/14/20101/14/20101/14/2010 2:55:57 PMPPASS
Kenneth Phone #: ###-####. Ok for perm occ. All issues were resolved.
BLD09-02113 BLD-Framing/Rough-in1/14/20101/14/20101/14/2010 2:55:22 PMPFAIL
eric Phone #: ###-####. Needs to provide engineering from truss co. for crushed bottom chord on 2 ply BG truss. Remove soffitt from north and south eaves ti verify the 2 layers of 5/8 type x rock. ok to insul. c/n posted. Also needs to have ESC issues resolved prior to next inspection.
ESC09-00757 General Inspection1/14/20101/14/20101/14/2010 2:32:09 PMPFAIL
Needs to remove all silts from hard surfaces. Needs to remove all blowable trash and construction debri from site or place in provided bin. c/n posted. Issues must be resolved prior to next inspection.
ESC09-00777 Random Inspection1/14/20101/14/20101/14/2010 1:49:37 PMPPASS
BLD09-02170 BLD-Foundation1/14/20101/14/20101/14/2010 1:49:26 PMPPASS
Dane Phone #: ###-####
ESC05-01274 Aging Inspection1/14/20101/14/20101/14/2010 12:28:18 PM DONE
ESC05-01274 DOC - Permit Expired1/14/20101/14/20101/14/2010 12:28:10 PMAPASS
Work was completed. It appears that stabalization was completed. Permit is expired.
ESC09-00790 Random Inspection1/14/20101/14/20101/14/2010 12:26:11 PMAPASS
ESC09-00792 Random Inspection1/14/20101/14/20101/14/2010 12:25:57 PMAPASS
ESC09-00270 Random Inspection1/14/20101/14/20101/14/2010 12:23:47 PMAPASS
BLD09-00737 BLD-Framing/Rough-in1/14/20101/14/20101/14/2010 12:23:26 PMAPASS
Framing / Energy seal Phone #: ###-#### Internet Inspection Request from: James Larkin
BLD09-02221 BLD-Footing1/13/20101/14/20101/14/2010 11:27:17 AMAPASS
retaining wall inspection ###-#### Internet Inspection Request from: Todd Blackwell
BLD09-02224 BLD-Footing1/13/20101/14/20101/14/2010 11:26:58 AMAPASS
retaining wall inspection Phone #: ###-#### Internet Inspection Request from: Todd Blackwell