ELE10-00018
| ELE-Aging Inspection | 1/14/2015 | 1/14/2015 | 1/15/2015 1:27:47 PM | | DONE |
|
|
Knocked on door, posted correction notice. 1-15-15 1:30 pm
|
ELE13-00524
| ELE-Aging Inspection | 1/14/2015 | 1/14/2015 | 1/15/2015 12:50:54 PM | | DONE |
|
|
posted notice on site, 1-15-15 12:50 pm
|
ELE15-00031
| Final | 1/14/2015 | 1/14/2015 | 1/14/2015 2:36:28 PM | P | PASS |
|
|
Bill Phone #: ###-#### Final OK
|
ELE15-00093
| Rough-In Permanent Service | 1/14/2015 | 1/14/2015 | 1/14/2015 2:17:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn RI OK PS, UG, N, OK
|
ELE14-03442
| Final | 1/9/2015 | 1/14/2015 | 1/14/2015 2:14:53 PM | P | PASS |
|
|
24 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. And 270 watt Suniva panels, ETL listed.
A single home run, in conduit, is ran from the solar array to the knife switch, located next to meter base on south side of home. From the knife switch to breaker in main panel, at the top of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode under the main panel.
The main panel is located outside, on the south corner, and there is no fences or pets so your all clear for access.
I am aware that Boise Inspectors want a rough-in inspection on these as of the new year, however this particular job was done electrically a couple weeks ago, and was only just connected to the panels. As always, give me a call if ya need anything -
Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King Final OK
|
ELE14-01910
| Final | 1/14/2015 | 1/14/2015 | 1/14/2015 1:17:18 PM | P | PASS |
|
|
Key is in the same location
Call Tim if needed
Thank you Phone #: ###-#### Inspection requested via web by John Harvey no inspection record of floor heat under tile, cable that can be seen is listed product corrections made, final OK
|
ELE14-03501
| Rough-In Permanent Service | 1/13/2015 | 1/14/2015 | 1/14/2015 12:40:26 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Zane Robertson WUI Zone, cans in soffit need 2 hour fire barrier prior to soffit cover. RI ok to cover interior, PS, UG, N, OK
|
ELE15-00088
| Electrical Rough-In | 1/14/2015 | 1/14/2015 | 1/14/2015 12:01:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Rohl Raise washer outlet, add another down lower, replace powder bath exhaust fan with new one, RI OK
|
ELE15-00085
| Electrical Rough-In | 1/13/2015 | 1/14/2015 | 1/14/2015 11:27:40 AM | A | PASS |
|
|
I will return once the skirting is on and attach the A/C flex. If you need inside the trailer the key is in the dryer vent. No one is living there. Phone #: ###-#### Inspection requested via web by Craig Korell Final OK
|
ELE15-00085
| Permanent Service | 1/14/2015 | 1/14/2015 | 1/14/2015 11:27:30 AM | P | PASS |
|
|
I will return once the skirting is on and attach the A/C flex. If you need inside the trailer the key is in the dryer vent. No one is living there. Phone #: ###-#### Inspection requested via web by Craig Korell PS, UG, N, OK
|
ELE14-03427
| Final | 1/13/2015 | 1/14/2015 | 1/14/2015 10:39:51 AM | A | PASS |
|
|
Tom Phone #: ###-#### FInal OK
|
ELE14-02665
| Final | 1/13/2015 | 1/14/2015 | 1/14/2015 10:11:28 AM | A | NH |
|
|
Robert Phone #: ###-####
no answer at door, left message for contractor
|
ELE14-02664
| Final | 1/13/2015 | 1/14/2015 | 1/14/2015 10:10:51 AM | A | PASS |
|
|
Robert Phone #: ###-#### Final OK
|
ELE15-00091
| Temporary Service | 1/13/2015 | 1/14/2015 | 1/14/2015 9:49:07 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe TS, UG, N, OK
|
ELE15-00075
| Final | 1/13/2015 | 1/14/2015 | 1/14/2015 9:39:52 AM | A | PASS |
|
|
correction made Phone #: ###-#### Inspection requested via web by Randy Fletcher corrections made, final OK
|
ELE14-02521
| Final | 1/13/2015 | 1/14/2015 | 1/14/2015 9:30:01 AM | A | PASS |
|
|
Nate Phone #: ###-#### Final OK
|
ELE14-01926
| Final | 1/13/2015 | 1/14/2015 | 1/14/2015 9:01:29 AM | A | FAIL |
|
|
Please call Zac for access at ###-####. He will meet and unlock for you. Phone #: ###-#### Inspection requested via web by Paula Gratiot left message for Jim 110.3B Listed or labeled equipment shall be installed in accordance to the listing and labeling 422.31 Permanently installed appliances shall have means of disconnect 210.12A Dwelling unit bedrooms shall have arc fault protection
|