Inspections for the day of: Wednesday, January 14, 2015.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCevyn Recla
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00018 ELE-Aging Inspection1/14/20151/14/20151/15/2015 1:27:47 PM DONE
Knocked on door, posted correction notice. 1-15-15 1:30 pm
ELE13-00524 ELE-Aging Inspection1/14/20151/14/20151/15/2015 12:50:54 PM DONE
posted notice on site, 1-15-15 12:50 pm
ELE15-00031 Final1/14/20151/14/20151/14/2015 2:36:28 PMPPASS
Bill Phone #: ###-####
Final OK
ELE15-00093 Rough-In Permanent Service1/14/20151/14/20151/14/2015 2:17:56 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
RI OK PS, UG, N, OK
ELE14-03442 Final1/9/20151/14/20151/14/2015 2:14:53 PMPPASS
24 solar panels.
AC micro-inverter system. No DC voltage.
Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed.
And 270 watt Suniva panels, ETL listed.

A single home run, in conduit, is ran from the solar array to the knife switch, located next to meter base on south side of home. From the knife switch to breaker in main panel, at the top of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.

The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode under the main panel.

The main panel is located outside, on the south corner, and there is no fences or pets so your all clear for access.

I am aware that Boise Inspectors want a rough-in inspection on these as of the new year, however this particular job was done electrically a couple weeks ago, and was only just connected to the panels. As always, give me a call if ya need anything -

Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King
Final OK
ELE14-01910 Final1/14/20151/14/20151/14/2015 1:17:18 PMPPASS
Key is in the same location

Call Tim if needed

Thank you Phone #: ###-#### Inspection requested via web by John Harvey
no inspection record of floor heat under tile, cable that can be seen is listed product
corrections made, final OK
ELE14-03501 Rough-In Permanent Service1/13/20151/14/20151/14/2015 12:40:26 PMPPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson
WUI Zone, cans in soffit need 2 hour fire barrier prior to soffit cover.
RI ok to cover interior, PS, UG, N, OK
ELE15-00088 Electrical Rough-In1/14/20151/14/20151/14/2015 12:01:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Rohl
Raise washer outlet, add another down lower, replace powder bath exhaust fan with new one, RI OK
ELE15-00085 Electrical Rough-In1/13/20151/14/20151/14/2015 11:27:40 AMAPASS
I will return once the skirting is on and attach the A/C flex. If you need inside the trailer the key is in the dryer vent. No one is living there. Phone #: ###-#### Inspection requested via web by Craig Korell
Final OK
ELE15-00085 Permanent Service1/14/20151/14/20151/14/2015 11:27:30 AMPPASS
I will return once the skirting is on and attach the A/C flex. If you need inside the trailer the key is in the dryer vent. No one is living there. Phone #: ###-#### Inspection requested via web by Craig Korell
PS, UG, N, OK
ELE14-03427 Final1/13/20151/14/20151/14/2015 10:39:51 AMAPASS
Tom Phone #: ###-####
FInal OK
ELE14-02665 Final1/13/20151/14/20151/14/2015 10:11:28 AMANH
Robert Phone #: ###-####

no answer at door, left message for contractor
ELE14-02664 Final1/13/20151/14/20151/14/2015 10:10:51 AMAPASS
Robert Phone #: ###-####
Final OK
ELE15-00091 Temporary Service1/13/20151/14/20151/14/2015 9:49:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe
TS, UG, N, OK
ELE15-00075 Final1/13/20151/14/20151/14/2015 9:39:52 AMAPASS
correction made Phone #: ###-#### Inspection requested via web by Randy Fletcher
corrections made, final OK
ELE14-02521 Final1/13/20151/14/20151/14/2015 9:30:01 AMAPASS
Nate Phone #: ###-####
Final OK
ELE14-01926 Final1/13/20151/14/20151/14/2015 9:01:29 AMAFAIL
Please call Zac for access at ###-####. He will meet and unlock for you. Phone #: ###-#### Inspection requested via web by Paula Gratiot
left message for Jim
110.3B Listed or labeled equipment shall be installed in accordance to the listing and labeling
422.31 Permanently installed appliances shall have means of disconnect
210.12A Dwelling unit bedrooms shall have arc fault protection