MEC20-00136
| Final | 1/14/2020 | 1/14/2020 | 1/14/2020 4:12:06 PM | P | NR |
|
|
Blake ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - A/C still needs electrical finished and locking caps installed - condensate pump needs safety wired - co sensors installed - need to see an electrical permit issued - re schedule inspection when work is finished - co sensors needs installed by final
|
MEC20-00136
| Pressure Test | 1/14/2020 | 1/14/2020 | 1/14/2020 4:09:04 PM | P | PASS |
|
|
Please inspect in the PM. Call on way: Blake ###-####. Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 5lb flue pressure test ok - 20lb gas pressure test ok - tagged meter location
|
MEC20-00118
| Final | 1/14/2020 | 1/14/2020 | 1/14/2020 3:27:46 PM | P | FAIL |
|
|
Unit #5 Inspection requested via web by Margie Rowe - A/C needs locking caps installed on service ports - pics of correction ok for final
|
MEC20-00130
| Final | 1/10/2020 | 1/14/2020 | 1/14/2020 2:34:55 PM | P | PASS |
|
|
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney - furnace ac coil co ok
|
MEC20-00170
| Final | 1/13/2020 | 1/14/2020 | 1/14/2020 1:52:30 PM | P | PASS |
|
|
Please call Gener on your way and inspect later PM - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace only co ok
|
MEC19-05047
| Final | 1/9/2020 | 1/14/2020 | 1/14/2020 1:36:33 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by James Cox - not an approved clearance reduction installed - install b vent to achieve clearances
|
MEC20-00144
| Final | 1/14/2020 | 1/14/2020 | 1/14/2020 1:20:00 PM | P | FAIL |
|
|
Inspection requested via web by Margie Rowe - A/C needs service clearances per manufactures specs
|
MEC19-04664
| Final | 1/9/2020 | 1/14/2020 | 1/14/2020 10:57:19 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - range vent needs installed and vented - need fireplace installation instructions onsite - A/C needs locking caps installed on service ports
|
MEC20-00172
| Final | 1/13/2020 | 1/14/2020 | 1/14/2020 10:39:04 AM | A | PASS |
|
|
Please call Mary prior to arrival if possible. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby - furnace only co ok
|
MEC19-05744
| Final | 1/9/2020 | 1/14/2020 | 1/14/2020 9:46:35 AM | A | PASS |
|
|
Please call Robert in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout - furnace ac coil co ok
|
MEC19-05712
| Final | 1/13/2020 | 1/14/2020 | 1/14/2020 9:20:23 AM | A | PASS |
|
|
call ###-#### anytime after 9am - final ok
|
MEC20-00144
| Final | 1/13/2020 | 1/14/2020 | 1/14/2020 9:20:08 AM | A | NH |
|
|
Inspection requested via web by Margie Rowe - no access to home left notice on front door
|
MEC20-00150
| Pressure Test | 1/13/2020 | 1/14/2020 | 1/14/2020 8:57:22 AM | A | PASS |
|
|
Pressure test and gas insert inspection. Please call Jason prior to arrival. Would like inspection as early as possible. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - 20lb gas pressure test ok
|
MEC20-00150
| Rough-in | 1/14/2020 | 1/14/2020 | 1/14/2020 8:57:05 AM | A | FAIL |
|
|
Pressure test and gas insert inspection. Please call Jason prior to arrival. Would like inspection as early as possible. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - CSST needs sleeved through masonary chimney - sags in gas line need more support - fireplace insert R/I ok
|
MEC19-02752
| Mec-Aging Inspection | 1/14/2020 | 1/14/2020 | 1/14/2020 8:05:00 AM | | FAIL |
|
|
Permit has not been active since 6-25-19. Schedule inspection with owner if work is finished. Permit will expired at next mechanical aging inspection if not active
|