Inspections for the day of: Wednesday, January 15, 2003.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-00544 ELE-Aging Inspection1/15/20031/15/20031/15/2003 12:00:00 AM NR
SUC 1/16/2003 9:55:00 AM
ELE02-00586 ELE-Aging Inspection1/15/20031/15/20031/15/2003 12:00:00 AM PASS
ELE02-00939 Final1/14/20031/15/20031/15/2003 12:00:00 AMADONE
Phone #: ###-#### Internet Inspection Request from: Andy Rose
ELE02-02806 Final1/14/20031/15/20031/15/2003 12:00:00 AMANR
fixed corrections as per jim schmere; Phone #: ###-#### Internet Inspection Request from: Andy Rose
ELE02-03716 Final1/14/20031/15/20031/15/2003 12:00:00 AMADONE
replaced service mast, tree fell across line.; Phone #: ###-#### Internet Inspection Request from: Andy Rose
ELE01-03660 Final1/14/20031/15/20031/15/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 01/14/2003 at 14:16:26. Contact: ###-####.gar door access is 2468
ELE02-01339 Final1/14/20031/15/20031/15/2003 12:00:00 AMPNH
Phone #: ###-#### Internet Inspection Request from: Andy Rose
no access 1/15/2003 4:41:19 PM
ELE03-00121 Temporary Service1/15/20031/15/20031/15/2003 12:00:00 AMPPASS
###-#### roger (Pat: This temp inspection is for a house that was due to fire... There are no building permits yet...Would you please check for work being done without bld permit and let me know)...Thanks Annette
ELE03-00122 Rough-In Permanent Service1/15/20031/15/20031/15/2003 12:00:00 AMPPASS
chad ###-####
P/S /H R Ok 1/15/2003 3:16:47 PM
ELE02-03628 Final1/15/20031/15/20031/15/2003 12:00:00 AMPCANC
kevin --key is at back door stuck in the trim on side of door ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ELE01-00500 Final1/15/20031/15/20031/15/2003 12:00:00 AMPFAIL
steven-- ###-#### or cell ###-####-received postcard--call 1st before insp Changed status from expired to issue per Jim Schmer
422.31 Disconnection of Permanently Connected Appliances.
Water heater requires a disconnect within sight or lock out on breaker.

210.52 Dwelling Unit Receptacle Outlets.
(B) Small Appliances.
(3) Kitchen Receptacle Requirements. Receptacles installed in a kitchen to serve countertop surfaces shall be supplied by not fewer than two small-appliance branch circuits,

210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.
(1) Bathrooms

1/15/2003 3:18:57 PM
ELE01-00500 Final1/15/20031/15/20031/15/2003 12:00:00 AMPFAIL
steven-- ###-#### or cell ###-####-received postcard--call 1st before insp
422.31 Disconnection of Permanently Connected Appliances.
Water heater requires a disconnect within sight or lock out on breaker.

210.52 Dwelling Unit Receptacle Outlets.
(B) Small Appliances.
(3) Kitchen Receptacle Requirements. Receptacles installed in a kitchen to serve countertop surfaces shall be supplied by not fewer than two small-appliance branch circuits,

210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.
(1) Bathrooms
1/15/2003 2:05:35 PM
ELE03-00094 Final1/15/20031/15/20031/15/2003 12:00:00 AMPFAIL
paul for homeowner call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
clearance in front of panel and from ground for service entrance conductors.
install "J" box instead of tape on romex above panel.
connect grounds properly 1/15/2003 4:14:41 PM
ELE02-02930 Final1/15/20031/15/20031/15/2003 12:00:00 AMPPASS
harold; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ELE03-00130 Electrical Rough-In1/15/20031/15/20031/15/2003 12:00:00 AMPPASS
underground pipe from house to attached garage ###-####